i550

i550-C3/400-3 i550-C3/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 3 kW/4 HP
  • Rated power LD 4 kW/5 HP
  • Output current 7.3/6.3 A
  • Output current LD 8.8/7.6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C4/230-3 i550-C4/230-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 4 kW/5 HP
  • Rated power LD 5.5 kW/7.5 HP
  • Output current 16.5 A
  • Output current LD 20.6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C4/400-3 i550-C4/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 4 kW/5 HP
  • Rated power LD 5.5 kW/7.5 HP
  • Output current 9.5/8.2 A
  • Output current LD 11.9/9.8 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C5.5/230-3 i550-C5.5/230-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 5.5 kW/7.5 HP
  • Rated power LD 7.5 kW/10 HP
  • Output current 23 A
  • Output current LD 27.6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C5.5/400-3 i550-C5.5/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 5.5 kW/7.5 HP
  • Rated power LD 7.5 kW/10 HP
  • Output current 13/11 A
  • Output current LD 15.6/13.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C7.5/400-3 i550-C7.5/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 7.5 kW/10 HP
  • Rated power LD 11 kW/15 HP
  • Output current 16.5/14 A
  • Output current LD 23/18.3 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C11/400-3 i550-C11/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 11 kW/15 HP
  • Rated power LD 15 kW/20 HP
  • Output current 23.5/21 A
  • Output current LD 28.2/25.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C15/400-3 i550-C15/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 15 kW/20 HP
  • Rated power LD 18.5 kW/25 HP
  • Output current 32/27 A
  • Output current LD 38.4/32.4 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C18/400-3 i550-C18/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 18.5 kW/25 HP
  • Rated power LD 22 kW/30 HP
  • Output current 40/34 A
  • Output current LD 48/40.8 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C22/400-3 i550-C22/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 22 kW/30 HP
  • Rated power LD 30 kW/40 HP
  • Output current 47/40.4 A
  • Output current LD 56.4/48.5 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C30/400-3 i550-C30/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 30 kW/40 HP
  • Rated power LD 37 kW/50 HP
  • Output current 61/52 A
  • Output current LD 73.2/62.4 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C37/400-3 i550-C37/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 37 kW/50 HP
  • Rated power LD 45 kW/60 HP
  • Output current 76/65 A
  • Output current LD 91.2/78 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C45/400-3 i550-C45/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 45 kW/60 HP
  • Rated power LD 55 kW/75 HP
  • Output current 89/77 A
  • Output current LD 107/92.4 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C55/400-3 i550-C55/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 55 kW/75 HP
  • Rated power LD 75 kW/100 HP
  • Output current 110/96 A
  • Output current LD 132/115 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C75/400-3 i550-C75/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 75 kW/100 HP
  • Rated power LD 90 kW/120 HP
  • Output current 150/124 A
  • Output current LD 180/149 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C90/400-3 i550-C90/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 90 kW/125 HP
  • Rated power LD 110 kW/150 HP
  • Output current 180/156 A
  • Output current LD 216/187 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C110/400-3 i550-C110/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 110 kW/150 HP
  • Rated power LD 132 kW/175 HP
  • Output current 212/180 A
  • Output current LD 254/216 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
← Previous Page 2 of 2
Showing 76–100 of 120
  • Fault message ID
    33154
    0x8182 Description

    CAN: bus off

    Keypad display
    CAN: bus off
    Cause

    Too many faulty frames have been received.

    • Defective cable (e. g. loose contact).
    • Two nodes with the same node address.
    Remedy
    • Check wiring of the network.
    • Check bus terminating resistor.
    • Set the identical baud rate for each node of the network.
    • Assign a unique node address to each node of the network.
    • Eliminate EMC interferences.
    Severity/response

    Trouble (configurable)

    • Change to the "Bus-Off" communication status.
  • Fault message ID
    33155
    0x8183 Description

    CAN: warning

    Keypad display
    CAN bus warning
    Cause

    Too many faulty frames have been received.

    • Defective cable (e. g. loose contact).
    • Two nodes with the same node address.
    Remedy
    • Check wiring of the network.
    • Check bus terminating resistor.
    • Set the identical baud rate for each node of the network.
    • Assign a unique node address to each node of the network.
    • Eliminate EMC interferences.
    Severity/response

    Warning (configurable)

  • Fault message ID
    33156
    0x8184 Description

    CAN: heartbeat time-out consumer 1

    Keypad display
    CAN heartb. C1
    Cause

    Within the heartbeat time 0x1016:001 (P520.01), no heartbeat telegram was received by node 1 to be monitored.

    Remedy
    • Check communication with the heartbeat producer.
    • Reactivate heartbeat producer.
    Severity/response

    Fault (configurable)

  • Fault message ID
    33157
    0x8185 Description

    CAN: heartbeat time-out consumer 2

    Keypad display
    CAN heartb. C2
    Cause

    Within the heartbeat time 0x1016:002 (P520.02), no heartbeat telegram was received by node 2 to be monitored.

    Remedy
    • Check communication with the heartbeat producer.
    • Reactivate heartbeat producer.
    Severity/response

    Fault (configurable)

  • Fault message ID
    33158
    0x8186 Description

    CAN: heartbeat time-out consumer 3

    Keypad display
    CAN heartb. C3
    Cause

    Within the heartbeat time 0x1016:003 (P520.03), no heartbeat telegram was received by node 3 to be monitored.

    Remedy
    • Check communication with the heartbeat producer.
    • Reactivate heartbeat producer.
    Severity/response

    Fault (configurable)

  • Fault message ID
    33159
    0x8187 Description

    CAN: heartbeat time-out consumer 4

    Keypad display
    CAN heartb. C4
    Cause

    Within the heartbeat time 0x1016:004 (P520.04), no heartbeat telegram was received by node 4 to be monitored.

    Remedy
    • Check communication with the heartbeat producer.
    • Reactivate heartbeat producer.
    Severity/response

    Fault (configurable)

  • Fault message ID
    33168
    0x8190 Description

    Network - Watchdog time-out

    Keypad display
    Watchdog timeout
    Cause

    Time-out during cyclic data reception, e.g. due to an interrupted communication link to the master or missing cyclic data.

    Remedy
    • Check wiring of the network.
    • Eliminate EMC interferences.
    Severity/response

    Trouble (configurable)

  • Fault message ID
    33169
    0x8191 Description

    Network - Disruption of cyclic data exchange

    Keypad display
    Cycl data error
    Cause

    The communication partner has interrupted the cyclic data exchange.

    Remedy
    • Check wiring of the network.
    • The slave must receive new parameterisation and configuration files by the master, in order to be able to exchange data again.
    Severity/response

    No response (configurable)

  • Fault message ID
    33170
    0x8192 Description

    Network - Initialization error

    Keypad display
    Net. Init. error
    Cause

    The initialisation of the communication stack has been interrupted due to an incorrect address setting or communication configuration.

    Remedy

    Check master/slave configuration and restart the devices.

    Severity/response

    Trouble (configurable)

  • Fault message ID
    33171
    0x8193 Description

    Network - Invalid cyclic process data

    Keypad display
    Inv. cyclic data
    Cause

    The cyclic process data received are invalid.

    Remedy

    Check cyclic process data sent by the master.

    Severity/response

    Trouble (configurable)

  • Fault message ID
    33185
    0x81A1 Description

    Modbus: network time-out

    Keypad display
    Modbus time-out
    Cause

    No valid messages have been received via the Modbus for a longer time than the time-out time set in 0x2858:002 (P515.02).

    Remedy
    • Check communication with the master.
    • Check wiring.
    • Check bus termination.
    Severity/response

    Fault (configurable)

  • Fault message ID
    33186
    0x81A2 Description

    Modbus: incorrect request by master

    Keypad display
    Modbus request
    Cause

    The request by the master is invalid, e. g. invalid CRC checksum, non-supported function code, or impermissible data access.

    Remedy

    Check request by the master:

    • Value in the valid range?
    • Function code valid?
    • No impermissible write access? (e. g. with regard to read-only parameters)
    Severity/response

    Warning The inverter (slave) responds to the master with an error code:

    • 0x01 = invalid function code
    • 0x02 = invalid data address
    • 0x03 = invalid data value
    • 0x04 = slave device failure
  • Fault message ID
    33200
    0x81B0 Description

    Network communication faulty

    Keypad display
    Comm. faulty
    Cause

    In case of the Ethernet communication interface, an internal software error has occurred.

    Remedy
    • Switch inverter off and on again.
    • In the event of a power failure during a firmware download, it is required to reload the firmware via the USB module and then restart the inverter.
    Severity/response

    Trouble

  • Fault message ID
    33381
    0x8265 Description

    POWERLINK: Loss of SoC

    Keypad display
    POWERLINK SoC
    Cause

    SoC of master was not received.

    Remedy

    Check configuration and system setup.

    Severity/response

    Trouble (configurable)

  • Fault message ID
    33382
    0x8266 Description

    POWERLINK: CRC error

    Keypad display
    POWERLINK CRC
    Cause

    CRC frame defective.

    Remedy

    Check system setup.

    Severity/response

    Trouble (configurable)

  • Fault message ID
    33414
    0x8286 Description

    Network - PDO mapping error

    Keypad display
    PDO map error
    Cause
    • Invalid PDO assignment by the master.
    • Internal PDO assignment was changed and does not comply with the configuration available in the master.
    Remedy

    Check data mapping in the master and slave.

    Severity/response

    Trouble (configurable) Setting parameters: 0x2859:003 (P515.03)

  • Fault message ID
    33425
    0x8291 Description

    CAN: RPDO1 time-out

    Keypad display
    Timeout RPDO1
    Cause

    RPDO1 was not received within the time-out period set in 0x1400:005 (P540.05) or with the sync configured.

    Severity/response

    Fault (configurable)

  • Fault message ID
    33426
    0x8292 Description

    CAN: RPDO2 time-out

    Keypad display
    Timeout RPDO2
    Cause

    RPDO2 was not received within the time-out period set in 0x1401:005 (P541.05) or with the sync configured.

    Severity/response

    Fault (configurable)

  • Fault message ID
    33427
    0x8293 Description

    CAN: RPDO3 time-out

    Keypad display
    Timeout RPDO3
    Cause

    RPDO3 was not received within the time-out period set in 0x1402:005 (P542.05) or with the sync configured.

    Severity/response

    Fault (configurable)

  • Fault message ID
    33553
    0x8311 Description

    Torque limit reached

    Keypad display
    Torque limit
    Cause

    Motor has reached the torque limit:

    • 0x2949:003 (P337.03): Actual positive torque limit
    • 0x2949:004 (P337.04): Actual negative torque limit
    Remedy
    • Observe load requirements.
    • Reduce motor load.
    • Check set torque limits and sources for the torque limits.
    Severity/response

    No response (configurable)

  • Fault message ID
    33664
    0x8380 Description

    Function not allowed in selected operating mode

    Keypad display
    Func. n. allowed
    Cause

    The selected function is not permissible in the chosen operating mode.

    • Selection of torque mode [-1] in 0x6060 (P301.00) with incompatible motor control in 0x2C00 (P300.00).
    • Selection of invalid drive mode [0] in 0x6060 (P301.00).
    Remedy
    • Note: selection of torque mode [-1] in 0x6060 (P301.00) with incompatible motor control in 0x2C00 (P300.00).
    • Check settings of operation modes.
    • 0x6060 (P301.00)
    Severity/response

    Warning

  • Fault message ID
    36992
    0x9080 Description

    Keypad removed

    Keypad display
    Keypad removed
    Cause

    The keypad was removed while the keypad control was activated.

    Remedy
    • Plug keypad back in or activate another control source.
    Severity/response

    Fault

  • Fault message ID
    65282
    0xFF02 Description

    Fault - Brake resistor overload

    Keypad display
    BrkResistor OL.F
    Cause

    The calculated thermal load of the brake resistor has reached the error threshold set in 0x2550:009 (P707.09). The regenerative energy is too high.

    Remedy
    • Check drive dimensioning.
    • Check settings for the brake energy management. Note: The error status will be reset if the thermal load falls below the error threshold - 20 %.
    Severity/response

    Fault (configurable)

    • The event can only be reset after a blocking time. Setting parameters: 0x2550:011 (P707.11)
  • Fault message ID
    65285
    0xFF05 Description

    Safety option - Internal error

    Keypad display
    Safety int.Error
    Cause

    The safety module or safety circuit of the device was detected as being defective. The integrated safety technology is defective.

    Remedy

    Hardware error: it is necessary to contact the manufacturer since the device must be replaced. The inverter must be replaced. Note! The user is not allowed to change inverters that come with integrated safety technology.

    • The safety module must not be removed.
    • The user must not carry out any repairs on the safety module.
    • The safety module is not a spare part.
    Severity/response

    Fault

    • The inverter is disabled immediately. The motor has no torque (is coasting).
    • The event can only be reset by mains switching.
  • Fault message ID
    65286
    0xFF06 Description

    Motor overspeed

    Keypad display
    Motor overspeed
    Cause

    The motor speed has reached the error threshold for overspeed set in 0x2D44:001 (P350.01).

    Remedy

    Adapt the maximum motor speed 0x6080 (P322.00) and the warning threshold or error threshold 0x2D44:001 (P350.01).

    Severity/response

    Fault (configurable)

    • The event can only be reset after a blocking time. Setting parameters: 0x2D44:002 (P350.02)
← Previous Page 4 of 5 Next →

No results.