i550

i550-C0.25/120-1 i550-C0.25/120-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.25 kW/0.33 HP
  • Output current 1.7 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 120 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C0.25/230-1 i550-C0.25/230-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.25 kW/0.33 HP
  • Output current 1.7 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C0.25/230-2 i550-C0.25/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.25 kW/0.33 HP
  • Output current 1.7 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C0.37/120-1 i550-C0.37/120-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.37 kW/0.5 HP
  • Output current 2.4 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 120 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C0.37/230-1 i550-C0.37/230-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.37 kW/0.5 HP
  • Output current 2.4 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C0.37/230-2 i550-C0.37/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.37 kW/0.5 HP
  • Output current 2.4 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C0.37/400-3 i550-C0.37/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.37 kW/0.5 HP
  • Output current 1.3/1.1 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C0.55/230-1 i550-C0.55/230-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.55 kW/0.75 HP
  • Output current 3.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C0.55/230-2 i550-C0.55/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.55 kW/0.75 HP
  • Output current 3.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C0.55/400-3 i550-C0.55/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.55 kW/0.75 HP
  • Output current 1.8/1.6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C0.75/120-1 i550-C0.75/120-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.75 kW/1 HP
  • Output current 4.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 120 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C0.75/230-1 i550-C0.75/230-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.75 kW/1 HP
  • Output current 4.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C0.75/230-2 i550-C0.75/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.75 kW/1 HP
  • Output current 4.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C0.75/400-3 i550-C0.75/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.75 kW/1 HP
  • Output current 2.4/2.1 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C1.1/120-1 i550-C1.1/120-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 1.1 kW/1.5 HP
  • Output current 6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 120 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C1.1/230-1 i550-C1.1/230-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 1.1 kW/1.5 HP
  • Output current 6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C1.1/230-2 i550-C1.1/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 1.1 kW/1.5 HP
  • Output current 6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C1.1/400-3 i550-C1.1/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 1.1 kW/1.5 HP
  • Output current 3.2/3 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C1.5/230-1 i550-C1.5/230-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 1.5 kW/2 HP
  • Output current 7 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C1.5/230-2 i550-C1.5/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 1.5 kW/2 HP
  • Output current 7 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C1.5/400-3 i550-C1.5/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 1.5 kW/2 HP
  • Output current 3.9/3.5 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C2.2/230-1 i550-C2.2/230-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 2.2 kW/3 HP
  • Output current 9.6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C2.2/230-2 i550-C2.2/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 2.2 kW/3 HP
  • Output current 9.6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C2.2/400-3 i550-C2.2/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 2.2 kW/3 HP
  • Output current 5.6/4.8 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
Page 1 of 2 Next →
Showing 26–50 of 120
  • Fault message ID
    17025
    0x4281 Description

    Heat sink fan warning

    Keypad display
    Heatsink fan
    Cause

    Warning of the heatsink fan.

    Remedy

    Clean fan and ventilation slots. If required, replace fan. The fans can be unlocked via locking hooks and can then be removed.

    Severity/response

    Warning

  • Fault message ID
    17029
    0x4285 Description

    PU overtemperature warning

    Keypad display
    Warn.PU Overtemp
    Cause

    The heatsink temperature of the power unit (display in 0x2D84:001 (P117.01)) has exceeded the warning threshold set in 0x2D84:002.

    • Ambient temperature too high.
    • Fan or ventilation slots are polluted.
    • Fan is defective.
    Remedy
    • Provide for a sufficient cooling of the device.
    • Clean fan and ventilation slots.
    • If required, replace fan.
    Severity/response

    Warning

  • Fault message ID
    17168
    0x4310 Description

    Motor overtemperature

    Keypad display
    Overtemp. motor
    Cause

    The motor temperature sensor connected to terminals X109/T1 and X109/T2 measures a too high motor temperature.

    • Motor too hot by impermissibly high currents.
    • Motor too hot by frequent and too long acceleration processes.
    Remedy
    • Check drive dimensioning.
    • Check motor temperature sensor and wiring.
    Severity/response

    Fault (configurable)

    • The event can only be reset after a blocking time.
  • Fault message ID
    20754
    0x5112 Description

    External supply voltage critical

    Keypad display
    Ext. supply low
    Cause

    External supply voltage failed or too low.

    Remedy
    • Check optional external 24V voltage supply (terminal X3/24E), if connected.
    • Check mains voltage.
    Severity/response

    Warning

  • Fault message ID
    20864
    0x5180 Description

    Overload 24 V supply

    Keypad display
    Overload 24V
    Cause

    Output current at the 24V output or at the digital outputs too high.

    Remedy

    Check 24V output and digital outputs for earth fault or overload.

    Severity/response

    Warning

  • Fault message ID
    21376
    0x5380 Description

    OEM hardware incompatible

    Keypad display
    Incomp. OEM HW
    Cause

    The control unit (OEM hardware) is not compatible with the power unit (OEM hardware).

    Remedy
    • Use compatible hardware.
    • Contact the OEM.
    Severity/response

    Fault

    • The inverter is disabled immediately. The motor has no torque (is coasting).
    • The event can only be reset by mains switching.
  • Fault message ID
    24970
    0x618A Description

    Warning - Internal fan

    Keypad display
    Internal fan
    Cause

    Warning of the internal fan.

    Remedy

    Check/replace internal fan.

    Severity/response

    Warning

  • Fault message ID
    25216
    0x6280 Description

    Trigger/functions connected incorrectly

    Keypad display
    P400 config err
    Cause

    The assignment directives have not been observed.

    • If the "flexible I/O configuration" is active as control source, the "Enable inverter" or "Run" function must be connected to a digital input in order that the motor can be stopped again any time!
    • The use of the "Start forward (CW)" and "Start reverse (CCW)" functions excludes the use of the "Run forward (CW)" and "Run reverse (CCW)" functions, and vice versa.
    Remedy

    Check and correct the assignment of the triggers to the functions.

    • With keypad or network control, the two "Enable inverter 0x2631:001 (P400.01)" and "Run 0x2631:002 (P400.02)" functions can also be set to "Constant TRUE [1]" to start the motor.
    Severity/response

    Trouble

  • Fault message ID
    25217
    0x6281 Description

    User-defined fault 1

    Keypad display
    User fault 1
    Cause

    Flexible I/O configuration: the "Activate fault 1" function was activated via the trigger selected in 0x2631:043 (P400.43).

    Remedy

    Eliminate error cause and then reset error.

    Severity/response

    Fault

  • Fault message ID
    25218
    0x6282 Description

    User-defined fault 2

    Keypad display
    User fault 2
    Cause

    Flexible I/O configuration: the "Activate fault 2" function was activated via the trigger selected in 0x2631:044 (P400.44).

    Remedy

    Eliminate error cause and then reset error.

    Severity/response

    Fault

  • Fault message ID
    25232
    0x6290 Description

    Warning invert rotation

    Keypad display
    Invert rotation
    Cause
    • Negative setpoint selection with an active limitation of rotation 0x283A (P304.00).
    • The "Reverse rotational direction" 0x2631:013 (P400.13) function was requested with an active limitation of rotation 0x283A (P304.00).
    Remedy
    • Check setpoint selection and trigger.
    • Check setting in 0x283A (P304.00).
    Severity/response

    Warning

    • The motor is brought to a standstill, since a reversal of the rotating direction is not permissible.
  • Fault message ID
    25233
    0x6291 Description

    Maximuml allowed troubles exceeded

    Keypad display
    Trouble overflow
    Cause

    The number of permitted restart attempts after a fault set in 0x2839:003 (P760.03) was exceeded. The fault occurred to frequently and could not be reset.

    Remedy

    Check and the eliminate the fault.

    Severity/response

    Fault

    • The motor remains at a standstill, no automatic restart is executed.
  • Fault message ID
    25248
    0x62A0 Description

    User-defined fault (LECOM)

    Keypad display
    UserFault(LECOM)
    Cause

    The "Activate fault" function was triggered via bit 10 of the LECOM control word 0x400B:002 (P592.02).

    Remedy

    Eliminate error cause and then reset error.

    Severity/response

    Fault

  • Fault message ID
    25249
    0x62A1 Description

    Network: user fault 1

    Keypad display
    Netw.UserFault 1
    Cause

    The "Activate fault 1" function was triggered via the NetWordIN1 data word 0x4008:001 (P590.01).

    Remedy

    Eliminate error cause and then reset error.

    Severity/response

    Fault

  • Fault message ID
    25250
    0x62A2 Description

    Network: user fault 2

    Keypad display
    Netw.UserFault 2
    Cause

    The "Activate fault 2" function was triggered via the NetWordIN1 data word 0x4008:001 (P590.01).

    Remedy

    Eliminate error cause and then reset error.

    Severity/response

    Fault

  • Fault message ID
    25265
    0x62B1 Description

    NetWordIN1 configuration incorrect

    Keypad display
    NetWordIN1 error
    Cause

    Two bits of the NetWordIN1 data word 0x4008:001 (P590.01) were assigned to the same function.

    Remedy

    Check and correct configuration of the NetWordIN1 data word.

    • The functions that are to be triggered via bits 0 ... 15 of the NetWordIN1 data word are defined in 0x400E:001 (P505.01) ... 0x400E:016 (P505.16).
    Severity/response

    Trouble

  • Fault message ID
    25266
    0x62B2 Description

    Changed device ID not yet active

    Keypad display
    Dev-ID changed
    Cause

    The device ID of the device was changed manually.

    Remedy

    1. Execute device command "Save user data" 0x2022:003 (P700.03). 2. Switch inverter off and on again.

    Severity/response

    Fault

  • Fault message ID
    25267
    0x62B3 Description

    Default settings not yet active

    Keypad display
    Settings error
    Cause

    The “Back-to-Box” system command has been executed. The standard parameter set has been written and saved. Communication is deactivated and the device is in stop status.

    Remedy

    Switch inverter off and on again.

    Severity/response

    Fault

  • Fault message ID
    25505
    0x63A1 Description

    CU: load error ID tag

    Keypad display
    CU ID tag error
    Cause

    Calibration data of the control unit not compatible or faulty.

    Remedy
    • Update firmware of the inverter to the most recent version.
    • If the error persists, the control unit or the device has to be replaced. In this case, please contact the manufacturer.
    Severity/response

    Fault

    • The inverter is disabled immediately. The motor has no torque (is coasting).
    • The event can only be reset by mains switching.
  • Fault message ID
    25506
    0x63A2 Description

    PU: load error ID tag

    Keypad display
    PU ID tag error
    Cause

    Calibration data of the power unit not compatible or faulty.

    Remedy
    • Update firmware of the inverter to the most recent version.
    • If the error persists, the power unit or the device has to be replaced. In this case, please contact the manufacturer.
    Severity/response

    Fault

    • The inverter is disabled immediately. The motor has no torque (is coasting).
    • The event can only be reset by mains switching.
  • Fault message ID
    25507
    0x63A3 Description

    Power unit unknown

    Keypad display
    PU unknown
    Cause

    The power unit installed is not supported by the software.

    Remedy

    Update firmware of the inverter to the most recent version.

    Severity/response

    Fault

    • The inverter is disabled immediately. The motor has no torque (is coasting).
    • The event can only be reset by mains switching.
  • Fault message ID
    28800
    0x7080 Description

    Assertion level monitoring (Low/High)

    Keypad display
    Assertionlevel
    Cause

    The last setting of the connection level differs from the saved setting.

    Remedy

    1. Execute device command "Save user data" 0x2022:003 (P700.03). 2. Switch inverter off and on again.

    Severity/response

    Fault

  • Fault message ID
    28801
    0x7081 Description

    Fault - Analog input 1

    Keypad display
    fault AI1
    Cause

    The monitoring function of the input signal configured for analog input 1 in 0x2636:008 (P430.08) and 0x2636:009 (P430.09) has been triggered.

    Remedy
    • Check input signal at analog input 1.
    • Check configuration of the monitoring function.
    Severity/response

    Fault (configurable) Setting parameters: 0x2636:010 (P430.10)

  • Fault message ID
    28802
    0x7082 Description

    Analog input 2 fault

    Keypad display
    AI2 fault
    Cause

    The monitoring function of the input signal configured for analog input 2 in 0x2637:008 (P431.08) and 0x2637:009 (P431.09) has been triggered.

    Remedy
    • Check input signal at analog input 2.
    • Check configuration of the monitoring function.
    Severity/response

    Fault (configurable) Setting parameters: 0x2637:010 (P431.10)

  • Fault message ID
    28803
    0x7083 Description

    HTL input fault

    Keypad display
    HTL input fault
    Severity/response

    No response (configurable) Setting parameters: 0x2641:006 (P416.06)

← Previous Page 2 of 5 Next →

No results.