6AV2124-1GC01-0AX0
SIMATIC HMI KP700 Comfort, Comfort Panel, key operation, 7" widescreen TFT display, 16 million colors, PROFINET interface, MPI/PROFIBUS DP interface, 12 MB configuration memory, Windows CE 6.0, configurable from WinCC Comfort V11.
Product category
Comfort panelsManufacturer
SIEMENSProduct series
S7-1200| General information | |
|---|---|
| Product type designation | KP700 Comfort |
| Display | |
| Design of display | TFT |
| Screen diagonal | 7 in |
| Display width | 152.4 mm |
| Display height | 91.4 mm |
| Number of colors | 16 777 216 |
| Resolution (pixels) | |
| Horizontal image resolution | 800 pixel |
| Vertical image resolution | 480 pixel |
| Backlighting | |
| MTBF backlighting (at 25 °C) | 80 000 h |
| Backlight dimmable | Yes; 0-100 % |
| Control elements | |
| Keyboard | |
| Function keys | |
| Number of function keys | 24 |
| Number of function keys with LEDs | 24 |
| Keys with LED | Yes |
| System keys | Yes |
| Numeric keyboard | Yes |
| alphanumeric keyboard | Yes; similar to mobile phone |
| Touch operation | |
| Design as touch screen | No; without |
| Expansions for operator control of the process | |
| DP direct LEDs (LEDs as S7 output I/O) | |
| F1...Fx | 24 |
| Direct keys (keys as S7 input I/O) | |
| F1...Fx | 24 |
| Direct keys (touch buttons as S7 input I/O) | 0 |
| Installation type/mounting | |
| Mounting position | vertical |
| Wall mounting/direct mounting | No |
| Mounting in portrait format possible | No |
| Mounting in landscape format possible | Yes |
| maximum permissible angle of inclination without external ventilation | 35° |
| Supply voltage | |
| Type of supply voltage | DC |
| Rated value (DC) | 24 V |
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Input current | |
| Current consumption (rated value) | 0.5 A |
| Starting current inrush I²t | 0.5 A²·s |
| Power | |
| Active power input, typ. | 12 W |
| Processor | |
| Processor type | X86 |
| Storage | |
| Flash | Yes |
| RAM | Yes |
| Memory available for user data | 12 Mbyte |
| Type of output | |
| Info LED | Yes |
| Power LED | No |
| Error LED | No |
| Acoustics | |
| Buzzer | No |
| Speaker | Yes |
| Time of day | |
| Clock | |
| Hardware clock (real-time) | Yes |
| Software clock | Yes |
| retentive | Yes; Back-up duration typically 6 weeks |
| synchronizable | Yes |
| Interfaces | |
| Number of industrial Ethernet interfaces | 1; 2 ports (switch) |
| Number of RS 485 interfaces | 1; RS 422 / 485 combined |
| Number of RS 422 interfaces | 1 |
| Number of RS 232 interfaces | 0 |
| Number of USB interfaces | 2; USB 2.0 |
| USB Mini B | 1; 5-pole |
| Number of 20 mA interfaces (TTY) | 0 |
| Number of parallel interfaces | 0 |
| Number of SD card slots | 2 |
| With software interfaces | No |
| Industrial Ethernet | |
| Industrial Ethernet status LED | 2 |
| Number of ports of the integrated switch | 2 |
| Protocols | |
| PROFINET | Yes |
| Supports protocol for PROFINET IO | Yes |
| IRT | Yes; As of WinCC V12 |
| PROFIBUS | Yes |
| EtherNet/IP | Yes |
| MPI | Yes |
| Protocols (Ethernet) | |
| TCP/IP | Yes |
| DHCP | Yes |
| SNMP | Yes |
| DCP | Yes |
| LLDP | Yes |
| WEB characteristics | |
| HTTP | Yes |
| HTTPS | Yes |
| HTML | Yes |
| XML | Yes |
| CSS | Yes |
| Active X | Yes |
| JavaScript | Yes |
| Java VM | No |
| Redundancy mode | |
| Media redundancy | |
| MRP | Yes; As of WinCC V12 |
| Further protocols | |
| CAN | No |
| MODBUS | Yes |
| Interrupts/diagnostics/status information | |
| Diagnoses | |
| Diagnostic information readable | Yes; S7 controller |
| EMC | |
| Emission of radio interference acc. to EN 55 011 | |
| Limit class A, for use in industrial areas | Yes |
| Limit class B, for use in residential areas | No |
| Degree and class of protection | |
| IP (at the front) | IP65 |
| IP (rear) | IP20 |
| NEMA (front) | |
| Enclosure Type 4 at the front | Yes |
| Enclosure Type 4x at the front | Yes |
| Standards, approvals, certificates | |
| CE mark | Yes |
| cULus | Yes |
| RCM (formerly C-TICK) | Yes |
| KC approval | Yes |
| Use in hazardous areas | |
| ATEX Zone 2 | Yes |
| ATEX Zone 22 | Yes |
| IECEx Zone 2 | Yes |
| IECEx Zone 22 | Yes |
| cULus Class I Zone 1 | No |
| cULus Class I Zone 2, Division 2 | Yes |
| FM Class I Division 2 | Yes |
| Marine approval | |
| Germanischer Lloyd (GL) | Yes |
| American Bureau of Shipping (ABS) | Yes |
| Bureau Veritas (BV) | Yes |
| Det Norske Veritas (DNV) | Yes |
| Lloyds Register of Shipping (LRS) | Yes |
| Nippon Kaiji Kyokai (Class NK) | Yes |
| Polski Rejestr Statkow (PRS) | No |
| Ambient conditions | |
| Ambient temperature during operation | |
| Operation (vertical installation) | |
| For vertical installation, min. | 0 °C |
| For vertical installation, max. | 50 °C; (55 °C, see entry ID: 64847814) |
| Operation (max. tilt angle) | |
| At maximum tilt angle, min. | 0 °C |
| At maximum tilt angle, max. | 40 °C |
| Operation (vertical installation, portrait format) | |
| For vertical installation, min. | 0 °C |
| For vertical installation, max. | 40 °C |
| Operation (max. tilt angle, portrait format) | |
| At maximum tilt angle, min. | 0 °C |
| At maximum tilt angle, max. | 35 °C |
| Ambient temperature during storage/transportation | |
| min. | -20 °C |
| max. | 60 °C |
| Relative humidity | |
| Operation, max. | 90 %; no condensation |
| Operating systems | |
| proprietary | No |
| pre-installed operating system | |
| Windows CE | Yes |
| Configuration | |
| Message indicator | Yes |
| Alarm system (incl. buffer and acknowledgment) | Yes |
| Process value display (output) | Yes |
| Process value default (input) possible | Yes |
| Recipe management | Yes |
| Configuration software | |
| STEP 7 Basic (TIA Portal) | No |
| STEP 7 Professional (TIA Portal) | No |
| WinCC flexible Compact | No |
| WinCC flexible Standard | No |
| WinCC flexible Advanced | No |
| WinCC Basic (TIA Portal) | No |
| WinCC Comfort (TIA Portal) | Yes; from V11 |
| WinCC Advanced (TIA Portal) | Yes; from V11 |
| WinCC Professional (TIA Portal) | Yes; from V11 |
| Languages | |
| Online languages | |
| Number of online/runtime languages | 32 |
| Project languages | |
| Languages per project | 32 |
| Functionality under WinCC (TIA Portal) | |
| Libraries | Yes |
| Applications/options | |
| Web browser | Yes |
| Pocket Word | Yes |
| Pocket Excel | Yes |
| PDF Viewer | Yes |
| Media Player | Yes |
| SIMATIC WinCC Sm@rtServer | Yes |
| SIMATIC WinCC Audit | Yes |
| Number of Visual Basic Scripts | Yes |
| Task planner | |
| time-controlled | Yes |
| task-controlled | Yes |
| Help system | |
| Number of characters per info text | 70 |
| Message system | |
| Number of alarm classes | 32 |
| Bit messages | Yes |
| Number of bit messages | 4 000 |
| Analog messages | Yes |
| Number of analog messages | 200 |
| S7 alarm number procedure | Yes |
| System messages HMI | Yes |
| System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... ) | Yes |
| Number of characters per message | 80 |
| Number of process values per message | 8 |
| Acknowledgment groups | Yes |
| Message indicator | Yes |
| Message buffer | |
| Number of entries | 1 024 |
| Circulating buffer | Yes |
| retentive | Yes |
| maintenance-free | Yes |
| Recipe management | |
| Number of recipes | 300 |
| Data records per recipe | 500 |
| Entries per data record | 1 000 |
| Size of internal recipe memory | 2 Mbyte |
| Recipe memory expandable | Yes |
| Variables | |
| Number of variables per device | 2 048 |
| Number of variables per screen | 400 |
| Limit values | Yes |
| Multiplexing | Yes |
| Structures | Yes |
| Arrays | Yes |
| Images | |
| Number of configurable images | 500 |
| Permanent window/default | Yes |
| Global image | Yes |
| Pop-up images | Yes |
| Slide-in images | Yes |
| Image selection by PLC | Yes |
| Image number in the PLC | Yes |
| Image objects | |
| Number of objects per image | 400 |
| Text fields | Yes |
| I/O fields | Yes |
| Graphic I/O fields (graphics list) | Yes |
| Symbolic I/O fields (text list) | Yes |
| Date/time fields | Yes |
| Switches | Yes |
| Buttons | Yes |
| Graphic display | Yes |
| Icons | Yes |
| Geometric objects | Yes |
| Complex image objects | |
| Number of complex objects per screen | 20 |
| Alarm view | Yes |
| Trend view | Yes |
| User view | Yes |
| Status/control | Yes |
| Sm@rtClient view | Yes |
| Recipe view | Yes |
| f(x) trend view | Yes |
| System diagnostics view | Yes |
| Media Player | Yes |
| HTML browser | Yes |
| PDF display | Yes |
| IP camera display | Yes |
| Bar graphs | Yes |
| Sliders | Yes |
| Pointer instruments | Yes |
| Analog/digital clock | Yes |
| Lists | |
| Number of text lists per project | 500 |
| Number of entries per text list | 500 |
| Number of graphics lists per project | 500 |
| Number of entries per graphics list | 500 |
| Archiving | |
| Number of archives per device | 50 |
| Number of entries per archive | 20 000 |
| Message archive | Yes |
| Process value archive | Yes |
| Archiving methods | |
| Sequential archive | Yes |
| Short-term archive | Yes |
| Memory location | |
| Memory card | Yes |
| USB memory | Yes |
| Ethernet | Yes |
| Data storage format | |
| CSV | Yes |
| TXT | Yes |
| RDB | Yes |
| Security | |
| Number of user groups | 50 |
| Number of user rights | 32 |
| Number of users | 50 |
| Password export/import | Yes |
| SIMATIC Logon | Yes |
| Logging through printer | |
| Alarms | Yes |
| Report (shift log) | Yes |
| Hardcopy | Yes |
| Electronic print to file | Yes; PDF, HTML |
| Character sets | |
| Keyboard fonts | |
| US English | Yes |
| Transfer (upload/download) | |
| MPI/PROFIBUS DP | Yes |
| USB | Yes |
| Ethernet | Yes |
| using external storage medium | Yes |
| Process coupling | |
| S7-1200 | Yes |
| S7-1500 | Yes |
| S7-200 | Yes |
| S7-300/400 | Yes |
| LOGO! | Yes |
| WinAC | Yes |
| SINUMERIK | Yes; with SINUMERIK option package |
| SIMOTION | Yes |
| Allen Bradley (EtherNet/IP) | Yes |
| Allen Bradley (DF1) | Yes |
| Mitsubishi (MC TCP/IP) | Yes |
| Mitsubishi (FX) | Yes |
| OMRON (FINS TCP) | No |
| OMRON (Host Link) | Yes |
| Modicon (Modbus TCP/IP) | Yes |
| Modicon (Modbus RTU) | Yes |
| OPC UA Client | Yes |
| OPC UA Server | Yes |
| Service tools/configuration aids | |
| Backup/Restore manually | Yes |
| Backup/Restore automatically | Yes |
| Simulation | Yes |
| Device switchover | Yes |
| Peripherals/Options | |
| Printer | Yes |
| SIMATIC HMI MM memory card: Multi Media Card | Yes; Up to 128 MB |
| SIMATIC HMI SD memory card: Secure Digital memory card | Yes; Up to 2 GB |
| SIMATIC HMI CF memory card Compact Flash Card | No |
| USB memory | Yes |
| SIMATIC IPC USB Flashdrive (USB stick) | Yes; Up to 16 GB |
| SIMATIC HMI USB stick | Yes; Up to 8 GB |
| Network camera | Yes |
| Mechanics/material | |
| Enclosure material (front) | |
| Plastic | No |
| Aluminum | Yes |
| Stainless steel | No |
| Dimensions | |
| Width of the housing front | 308 mm |
| Height of housing front | 204 mm |
| Mounting cutout, width | 282 mm |
| Mounting cutout, height | 178 mm |
| mounting depth | 63 mm |
| Weights | |
| Weight (without packaging) | 2.2 kg |
| Weight (with packaging) | 2.8 kg |
| Approvals / Certificates | |