Parameters

Filters
Title Parameter Display Code Data type Default setting Attributes Fieldbus Manufacturer Product category Operations
0x4049 PID I- component P602.00 U16 400 ms general Lenze i550
0x404A PID D-component P603.00 U8 0.0 s general Lenze i550
0x404B PID setpoint ramp P604.00 U16 20.0 s general Lenze i550
0x404C:001 PID influence: Acceleration time for activation P607.01 U16 5.0 s general Lenze i550
0x404C:002 PID influence: Deceleration time for masking out P607.02 U16 5.0 s general Lenze i550
0x404C:003 PID influence: PID influence factor P607.03 I16 100.0 % general Lenze i550
0x404D:001 PID alarms: MIN alarm threshold P608.01 I16 0.00 PID unit general Lenze i550
0x404D:002 PID alarms: MAX alarm threshold P608.02 I16 100.00 PID unit general Lenze i550
0x404D:003 PID alarms: Monitoring bandwidth PID feedback signal P608.03 U16 2.00 % general Lenze i550
0x404E:001 PID setpoint limits: Minimum setpoint P605.01 I16 -300.00 PID unit general Lenze i550
0x404E:002 PID setpoint limits: Maximum setpoint P605.02 I16 300.00 PID unit general Lenze i550
0x405C:001 Pump cascading: Operating mode P770.01 U8 Disabled [0] Lenze i550
0x405C:002 Pump cascading: Priority at startup P770.02 U8 By operating time [1] Lenze i550
0x405C:003 Pump cascading: Start frequency P770.03 U16 40.0 Hz Lenze i550
0x405C:004 Pump cascading: Stop frequency P770.04 U16 10.0 Hz Lenze i550
0x405C:005 Pump cascading: Settling time P770.05 U16 5.0 s Lenze i550
0x405C:006 Pump cascading: Delay time P770.06 U16 2.0 s Lenze i550
0x405C:007 Pump cascading: Lower frequency threshold P770.07 U16 20.0 Hz Lenze i550
0x405C:008 Pump cascading: Upper frequency threshold P770.08 U16 30.0 Hz Lenze i550
0x405C:009 Pump cascading: Automatic runtime P770.09 U16 0 h Lenze i550
0x405C:010 Pump cascading: Automatic transition time P770.10 I16 0.0 s Lenze i550
0x405C:011 Pump cascading: Reset operating time P770.11 U8 Disabled [0] Lenze i550
0x405C:012 Pump cascading: Status word P770.12 U16 - (Read only) Lenze i550
0x405C:013 Pump cascading: Operating time pump 1 P770.13 U32 x s (Read only) Lenze i550
0x405C:014 Pump cascading: Operating time pump 2 P770.14 U32 x s (Read only) Lenze i550
0x5810:001 Application diagnostics: Application state U8 - (Read only) - Lenze i950
0x5850:001 EtherCAT master commands: Restart communication U16 No action/no error [0] - Lenze i950
0x5851:001 EtherCAT master diagnosis: EtherCAT master state U16 - (Read only) - Lenze i950
0x5851:002 EtherCAT master diagnosis: EtherCAT master state summary U32 - (Read only) H Lenze i950
0x5851:003 EtherCAT master diagnosis: EtherCAT error U16 - (Read only) - Lenze i950
0x5851:004 EtherCAT master diagnosis: Bus scan match U8 - (Read only) - Lenze i950
0x5851:005 EtherCAT master diagnosis: Configured cycle time U32 - (Read only) - Lenze i950
0x5851:006 EtherCAT master diagnosis: Connected slaves U16 - (Read only) - Lenze i950
0x5851:007 EtherCAT master diagnosis: Configured slaves U16 - (Read only) - Lenze i950
0x5860:001 EtherCAT slaves station addresses: Station address slave 1 I16 - (Read only) - Lenze i950
0x5860:002 EtherCAT slaves station addresses: Station address slave 2 I16 - (Read only) - Lenze i950
0x5860:003 EtherCAT slaves station addresses: Station address slave 3 I16 - (Read only) - Lenze i950
0x5860:004 EtherCAT slaves station addresses: Station address slave 4 I16 - (Read only) - Lenze i950
0x5860:005 EtherCAT slaves station addresses: Station address slave 5 I16 - (Read only) - Lenze i950
0x5860:006 EtherCAT slaves station addresses: Station address slave 6 I16 - (Read only) - Lenze i950
0x5860:007 EtherCAT slaves station addresses: Station address slave 7 I16 - (Read only) - Lenze i950
0x5860:008 EtherCAT slaves station addresses: Station address slave 8 I16 - (Read only) - Lenze i950
0x5860:009 EtherCAT slaves station addresses: Station address slave 9 I16 - (Read only) - Lenze i950
0x5860:010 EtherCAT slaves station addresses: Station address slave 10 I16 - (Read only) - Lenze i950
0x5860:011 EtherCAT slaves station addresses: Station address slave 11 I16 - (Read only) - Lenze i950
0x5860:012 EtherCAT slaves station addresses: Station address slave 12 I16 - (Read only) - Lenze i950
0x5860:013 EtherCAT slaves station addresses: Station address slave 13 I16 - (Read only) - Lenze i950
0x5860:014 EtherCAT slaves station addresses: Station address slave 14 I16 - (Read only) - Lenze i950
0x5860:015 EtherCAT slaves station addresses: Station address slave 15 I16 - (Read only) - Lenze i950
0x5860:016 EtherCAT slaves station addresses: Station address slave 16 I16 - (Read only) - Lenze i950
← Previous Page 53 of 58 Next →