Parameters
Filters
| Title | Parameter | Display Code | Data type | Default setting | Attributes | Fieldbus | Manufacturer | Product category | Operations |
|---|---|---|---|---|---|---|---|---|---|
| 0x4049 | PID I- component | P602.00 | U16 | 400 ms | general | Lenze | i550 | ||
| 0x404A | PID D-component | P603.00 | U8 | 0.0 s | general | Lenze | i550 | ||
| 0x404B | PID setpoint ramp | P604.00 | U16 | 20.0 s | general | Lenze | i550 | ||
| 0x404C:001 | PID influence: Acceleration time for activation | P607.01 | U16 | 5.0 s | general | Lenze | i550 | ||
| 0x404C:002 | PID influence: Deceleration time for masking out | P607.02 | U16 | 5.0 s | general | Lenze | i550 | ||
| 0x404C:003 | PID influence: PID influence factor | P607.03 | I16 | 100.0 % | general | Lenze | i550 | ||
| 0x404D:001 | PID alarms: MIN alarm threshold | P608.01 | I16 | 0.00 PID unit | general | Lenze | i550 | ||
| 0x404D:002 | PID alarms: MAX alarm threshold | P608.02 | I16 | 100.00 PID unit | general | Lenze | i550 | ||
| 0x404D:003 | PID alarms: Monitoring bandwidth PID feedback signal | P608.03 | U16 | 2.00 % | general | Lenze | i550 | ||
| 0x404E:001 | PID setpoint limits: Minimum setpoint | P605.01 | I16 | -300.00 PID unit | general | Lenze | i550 | ||
| 0x404E:002 | PID setpoint limits: Maximum setpoint | P605.02 | I16 | 300.00 PID unit | general | Lenze | i550 | ||
| 0x405C:001 | Pump cascading: Operating mode | P770.01 | U8 | Disabled [0] | Lenze | i550 | |||
| 0x405C:002 | Pump cascading: Priority at startup | P770.02 | U8 | By operating time [1] | Lenze | i550 | |||
| 0x405C:003 | Pump cascading: Start frequency | P770.03 | U16 | 40.0 Hz | Lenze | i550 | |||
| 0x405C:004 | Pump cascading: Stop frequency | P770.04 | U16 | 10.0 Hz | Lenze | i550 | |||
| 0x405C:005 | Pump cascading: Settling time | P770.05 | U16 | 5.0 s | Lenze | i550 | |||
| 0x405C:006 | Pump cascading: Delay time | P770.06 | U16 | 2.0 s | Lenze | i550 | |||
| 0x405C:007 | Pump cascading: Lower frequency threshold | P770.07 | U16 | 20.0 Hz | Lenze | i550 | |||
| 0x405C:008 | Pump cascading: Upper frequency threshold | P770.08 | U16 | 30.0 Hz | Lenze | i550 | |||
| 0x405C:009 | Pump cascading: Automatic runtime | P770.09 | U16 | 0 h | Lenze | i550 | |||
| 0x405C:010 | Pump cascading: Automatic transition time | P770.10 | I16 | 0.0 s | Lenze | i550 | |||
| 0x405C:011 | Pump cascading: Reset operating time | P770.11 | U8 | Disabled [0] | Lenze | i550 | |||
| 0x405C:012 | Pump cascading: Status word | P770.12 | U16 | - (Read only) | Lenze | i550 | |||
| 0x405C:013 | Pump cascading: Operating time pump 1 | P770.13 | U32 | x s (Read only) | Lenze | i550 | |||
| 0x405C:014 | Pump cascading: Operating time pump 2 | P770.14 | U32 | x s (Read only) | Lenze | i550 | |||
| 0x5810:001 | Application diagnostics: Application state | U8 | - (Read only) | - | Lenze | i950 | |||
| 0x5850:001 | EtherCAT master commands: Restart communication | U16 | No action/no error [0] | - | Lenze | i950 | |||
| 0x5851:001 | EtherCAT master diagnosis: EtherCAT master state | U16 | - (Read only) | - | Lenze | i950 | |||
| 0x5851:002 | EtherCAT master diagnosis: EtherCAT master state summary | U32 | - (Read only) | H | Lenze | i950 | |||
| 0x5851:003 | EtherCAT master diagnosis: EtherCAT error | U16 | - (Read only) | - | Lenze | i950 | |||
| 0x5851:004 | EtherCAT master diagnosis: Bus scan match | U8 | - (Read only) | - | Lenze | i950 | |||
| 0x5851:005 | EtherCAT master diagnosis: Configured cycle time | U32 | - (Read only) | - | Lenze | i950 | |||
| 0x5851:006 | EtherCAT master diagnosis: Connected slaves | U16 | - (Read only) | - | Lenze | i950 | |||
| 0x5851:007 | EtherCAT master diagnosis: Configured slaves | U16 | - (Read only) | - | Lenze | i950 | |||
| 0x5860:001 | EtherCAT slaves station addresses: Station address slave 1 | I16 | - (Read only) | - | Lenze | i950 | |||
| 0x5860:002 | EtherCAT slaves station addresses: Station address slave 2 | I16 | - (Read only) | - | Lenze | i950 | |||
| 0x5860:003 | EtherCAT slaves station addresses: Station address slave 3 | I16 | - (Read only) | - | Lenze | i950 | |||
| 0x5860:004 | EtherCAT slaves station addresses: Station address slave 4 | I16 | - (Read only) | - | Lenze | i950 | |||
| 0x5860:005 | EtherCAT slaves station addresses: Station address slave 5 | I16 | - (Read only) | - | Lenze | i950 | |||
| 0x5860:006 | EtherCAT slaves station addresses: Station address slave 6 | I16 | - (Read only) | - | Lenze | i950 | |||
| 0x5860:007 | EtherCAT slaves station addresses: Station address slave 7 | I16 | - (Read only) | - | Lenze | i950 | |||
| 0x5860:008 | EtherCAT slaves station addresses: Station address slave 8 | I16 | - (Read only) | - | Lenze | i950 | |||
| 0x5860:009 | EtherCAT slaves station addresses: Station address slave 9 | I16 | - (Read only) | - | Lenze | i950 | |||
| 0x5860:010 | EtherCAT slaves station addresses: Station address slave 10 | I16 | - (Read only) | - | Lenze | i950 | |||
| 0x5860:011 | EtherCAT slaves station addresses: Station address slave 11 | I16 | - (Read only) | - | Lenze | i950 | |||
| 0x5860:012 | EtherCAT slaves station addresses: Station address slave 12 | I16 | - (Read only) | - | Lenze | i950 | |||
| 0x5860:013 | EtherCAT slaves station addresses: Station address slave 13 | I16 | - (Read only) | - | Lenze | i950 | |||
| 0x5860:014 | EtherCAT slaves station addresses: Station address slave 14 | I16 | - (Read only) | - | Lenze | i950 | |||
| 0x5860:015 | EtherCAT slaves station addresses: Station address slave 15 | I16 | - (Read only) | - | Lenze | i950 | |||
| 0x5860:016 | EtherCAT slaves station addresses: Station address slave 16 | I16 | - (Read only) | - | Lenze | i950 |