Parameters
Filters
| Title | Parameter | Display Code | Data type | Default setting | Fieldbus | Manufacturer | Product category | Operations |
|---|---|---|---|---|---|---|---|---|
| 0x402C:005 | Sequencer segment 7: Analog outputs | P807.05 | U16 | 0.00 VDC | Sequencer | Lenze | i550 | |
| 0x402C:006 | Sequencer segment 7: PID setpoint | P807.06 | I16 | 0.00 PID unit | Sequencer | Lenze | i550 | |
| 0x402C:007 | Sequencer segment 7: Torque setpoint | P807.07 | I16 | 100.0 % | Sequencer | Lenze | i550 | |
| 0x402C:008 | Sequencer segment 7: NetWordOUT2 | U16 | 0 | Sequencer | Lenze | i550 | ||
| 0x402C:009 | Sequencer segment 7: Reserved | U32 | 0 | Sequencer | Lenze | i550 | ||
| 0x402D:001 | Sequencer segment 8: Frequency setpoint | P808.01 | I16 | 0.0 Hz | Sequencer | Lenze | i550 | |
| 0x402D:002 | Sequencer segment 8: Acceleration/deceleration | P808.02 | U16 | 5.0 s | Sequencer | Lenze | i550 | |
| 0x402D:003 | Sequencer segment 8: Time | P808.03 | U32 | 0.0 s | Sequencer | Lenze | i550 | |
| 0x402D:004 | Sequencer segment 8: Digital outputs | P808.04 | U8 | 0 | Sequencer | Lenze | i550 | |
| 0x402D:005 | Sequencer segment 8: Analog outputs | P808.05 | U16 | 0.00 VDC | Sequencer | Lenze | i550 | |
| 0x402D:006 | Sequencer segment 8: PID setpoint | P808.06 | I16 | 0.00 PID unit | Sequencer | Lenze | i550 | |
| 0x402D:007 | Sequencer segment 8: Torque setpoint | P808.07 | I16 | 100.0 % | Sequencer | Lenze | i550 | |
| 0x402D:008 | Sequencer segment 8: NetWordOUT2 | U16 | 0 | Sequencer | Lenze | i550 | ||
| 0x402D:009 | Sequencer segment 8: Reserved | U32 | 0 | Sequencer | Lenze | i550 | ||
| 0x402E:001 | End segment: Frequency setpoint | P822.01 | I16 | 0.0 Hz | Sequencer | Lenze | i550 | |
| 0x402E:002 | End segment: Acceleration/deceleration | P822.02 | U16 | 5.0 s | Sequencer | Lenze | i550 | |
| 0x402E:003 | End segment: Time | P822.03 | U32 | 0.0 s | Sequencer | Lenze | i550 | |
| 0x402E:004 | End segment: Digital outputs | P822.04 | U8 | 0 | Sequencer | Lenze | i550 | |
| 0x402E:005 | End segment: Analog outputs | P822.05 | U16 | 0.00 VDC | Sequencer | Lenze | i550 | |
| 0x402E:006 | End segment: PID setpoint | P822.06 | I16 | 0.00 PID unit | Sequencer | Lenze | i550 | |
| 0x402E:007 | End segment: Torque setpoint | P822.07 | I16 | 100.0 % | Sequencer | Lenze | i550 | |
| 0x402E:008 | End segment: NetWordOUT2 | U16 | 0 | Sequencer | Lenze | i550 | ||
| 0x402E:009 | End segment: Reserved | U32 | 0 | Sequencer | Lenze | i550 | ||
| 0x402F | End of sequence mode | P824.00 | U8 | Keep running [0] | Sequencer | Lenze | i550 | |
| 0x4030:001 ... 0x4030:016 | Sequence 1: Step 1 ... Step 16 | P830.01 ... 16 | I8 | Skip step [0] | Sequencer | Lenze | i550 | |
| 0x4031 | Number of cycles sequence 1 | P831.00 | U16 | 1 | Sequencer | Lenze | i550 | |
| 0x4032:001 ... 0x4032:016 | Sequence 2: Step 1 ... Step 16 | P835.01 ... 16 | I8 | Skip step [0] | Sequencer | Lenze | i550 | |
| 0x4033 | Number of cycles sequence 2 | P836.00 | U16 | 1 | Sequencer | Lenze | i550 | |
| 0x4034:001 ... 0x4034:016 | Sequence 3: Step 1 ... Step 16 | P840.01 ... 16 | I8 | Skip step [0] | Sequencer | Lenze | i550 | |
| 0x4035 | Number of cycles sequence 3 | P841.00 | U16 | 1 | Sequencer | Lenze | i550 | |
| 0x4036:001 ... 0x4036:016 | Sequence 4: Step 1 ... Step 16 | P845.01 ... 16 | I8 | Skip step [0] | Sequencer | Lenze | i550 | |
| 0x4037 | Number of cycles sequence 4 | P846.00 | U16 | 1 | Sequencer | Lenze | i550 | |
| 0x4038:001 ... 0x4038:016 | Sequence 5: Step 1 ... Step 16 | P850.01 ... 16 | I8 | Skip step [0] | Sequencer | Lenze | i550 | |
| 0x4039 | Number of cycles sequence 5 | P851.00 | U16 | 1 | Sequencer | Lenze | i550 | |
| 0x403A:001 ... 0x403A:016 | Sequence 6: Step 1 ... Step 16 | P855.01 ... 16 | I8 | Skip step [0] | Sequencer | Lenze | i550 | |
| 0x403B | Number of cycles sequence 6 | P856.00 | U16 | 1 | Sequencer | Lenze | i550 | |
| 0x403C:001 ... 0x403C:016 | Sequence 7: Step 1 ... Step 16 | P860.01 ... 16 | I8 | Skip step [0] | Sequencer | Lenze | i550 | |
| 0x403D | Number of cycles sequence 7 | P861.00 | U16 | 1 | Sequencer | Lenze | i550 | |
| 0x403E:001 ... 0x403E:016 | Sequence 8: Step 1 ... Step 16 | P865.01 ... 16 | I8 | Skip step [0] | Sequencer | Lenze | i550 | |
| 0x403F | Number of cycles sequence 8 | P866.00 | U16 | 1 | Sequencer | Lenze | i550 | |
| 0x4040 | Start of sequence mode | P820.00 | U8 | Restart sequencer [0] | Sequencer | Lenze | i550 | |
| 0x4041:001 ... 0x4041:032 | Parameter change-over: Parameter 1 ... Parameter 32 | P750.01 ... 32 | IDX | 0x00000000 | general | Lenze | i550 | |
| 0x4042:001 ... 0x4042:032 | Parameter value set 1: Value of parameter 1 ... Value of parameter 32 | P751.01 ... 32 | I32 | 0 | general | Lenze | i550 | |
| 0x4043:001 ... 0x4043:032 | Parameter value set 2: Value of parameter 1 ... Value of parameter 32 | P752.01 ... 32 | I32 | 0 | general | Lenze | i550 | |
| 0x4044:001 ... 0x4044:032 | Parameter value set 3: Value of parameter 1 ... Value of parameter 32 | P753.01 ... 32 | I32 | 0 | general | Lenze | i550 | |
| 0x4045:001 ... 0x4045:032 | Parameter value set 4: Value of parameter 1 ... Value of parameter 32 | P754.01 ... 32 | I32 | 0 | general | Lenze | i550 | |
| 0x4046 | Activation of parameter set | P755.00 | U8 | Via command (disable required) [0] | general | Lenze | i550 | |
| 0x4047:001 | Parameter change-over error message: Status | P756.01 | U16 | - (Read only) | general | Lenze | i550 | |
| 0x4047:002 | Parameter change-over error message: List entry | P756.02 | U8 | - (Read only) | general | Lenze | i550 | |
| 0x4048 | PID P-component | P601.00 | U16 | 5.0 % | general | Lenze | i550 |