6ES7515-2RN03-0AB0

6ES7515-2RN03-0AB0

SIMATIC S7-1500R, CPU 1515R-2 PN, központi egység 1 MB munkamemóriával a programhoz és 4.5 MB-tal az adatokhoz, 1. interfész: PROFINET RT 2 portos switch-csel, 2. interfész: PROFINET, SIMATIC Memory Card szükséges.

Termékkategória
CPU
Gyártó
SIEMENS
Termékcsalád
S7-1500
General information
Product type designationCPU 1515R-2 PN
HW functional statusFS05
Firmware versionV4.1
FW update possibleYes
Product function
I&M dataYes; I&M0 to I&M3
Isochronous modeNo
SysLogYes
Engineering with
STEP 7 TIA Portal configurable/integrated from versionV21 (FW V4.1) / V18 (FW V3.0); with older TIA Portal versions configurable as 6ES7515-2RM00-0AB0
Redundancy
stand-alone operationYes
CiR - Configuration in RUN
Configuration in Run (CiR) possibleYes; V21.0 (FW V4.1) CiR functions: adding an IO device; reparameterizing an I/O module
Display
Screen diagonal [cm]6.1 cm
Control elements
Number of keys8
Mode buttons2
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Mains buffering
Mains/voltage failure stored energy time5 ms
Repeat rate, min.1/s
Input current
Current consumption (rated value)0.65 A
Current consumption, max.0.88 A
Inrush current, max.1.15 A
I²t0.6 A²·s
Power
Infeed power to the backplane bus12 W
Power consumption from the backplane bus (balanced)6.2 W
Power loss
Power loss, typ.3.6 W
Storage
Number of slots for SIMATIC memory card1
SIMATIC memory card requiredYes
Work memory
integrated (for program)1 Mbyte
integrated (for data)4.5 Mbyte
Load memory
Plug-in (SIMATIC Memory Card), max.32 Gbyte
Backup
maintenance-freeYes
CPU processing times
for bit operations, typ.20 ns
for word operations, typ.24 ns
for fixed point arithmetic, typ.32 ns
for floating point arithmetic, typ.128 ns
CPU-blocks
Number of elements (total)8 000; Blocks (OB, FB, FC, DB) and UDTs
DB
Number range1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
Size, max.4.5 Mbyte; For non-optimized block accesses, the max. size of the DB is 64 KB
FB
Number range0 ... 65 535
Size, max.1 Mbyte
FC
Number range0 ... 65 535
Size, max.1 Mbyte
OB
Size, max.1 Mbyte
Number of free cycle OBs100
Number of time alarm OBs20
Number of delay alarm OBs20
Number of cyclic interrupt OBs20; with minimum OB 3x cycle of 10 ms
Number of process alarm OBs50
Number of DPV1 alarm OBs3
Number of startup OBs100
Number of asynchronous error OBs4
Number of synchronous error OBs2
Number of diagnostic alarm OBs1
Nesting depth
per priority class24
Counters, timers and their retentivity
S7 counter
Number2 048
Retentivity
adjustableYes
IEC counter
NumberAny (only limited by the main memory)
Retentivity
adjustableYes
S7 timer
Number2 048
Retentivity
adjustableYes
IEC timer
NumberAny (only limited by the main memory)
Retentivity
can be setYes
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.472 kbyte; in total; for bit memories, timers, counters, DBs, and technology data (axes)
Extended retentive data area (incl. timers, counters, flags), max.4.5 Mbyte; When using PS 6 0W 24/48/60 V DC HF
Flag
Size, max.16 kbyte
Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
Retentivity adjustableYes
Retentivity presetNo
Local data
per priority class, max.64 kbyte; max. 16 KB per block
Address area
Number of IO modules4 096; max. number of modules / submodules
I/O address area
Inputs32 kbyte; All inputs are in the process image
Outputs32 kbyte; All outputs are in the process image
per integrated IO subsystem
Inputs (volume)8 kbyte
Outputs (volume)8 kbyte
Subprocess images
Number of subprocess images, max.31
Hardware configuration
Number of distributed IO systems16; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET, but also by the connection of I/O via IE/PB-Links.
Number of IO Controllers
Integrated1
Rack
Modules per rack, max.5; CPU + 2 PS + 2 CP
Time of day
Clock
TypeHardware clock
Backup time6 wk; At 40 °C ambient temperature, typically
Deviation per day, max.10 s; Typ.: 2 s
Operating hours counter
Number64
Clock synchronization
supportedYes
on Ethernet via NTPYes
Interfaces
Number of PROFINET interfaces2
1. Interface
Interface types
RJ 45 (Ethernet)Yes; X1
Number of ports2
integrated switchYes
Protocols
IP protocolYes; IPv4
PROFINET IO ControllerYes
PROFINET IO deviceNo
SIMATIC communicationYes; Only Server
Open IE communicationYes; Optionally also encrypted
Web serverYes
Media redundancyYes
PROFINET IO Controller
Services
Isochronous modeNo
IRTNo
Dynamic Frame Packing (DFP)No
PROFIenergyYes; per user program
Prioritized startupNo
Number of connectable IO Devices, max.64
Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
Update time for RT
for send cycle of 1 ms1 ms to 512 ms
2. Interface
Interface types
RJ 45 (Ethernet)Yes; X2
Number of ports1
integrated switchNo
Protocols
IP protocolYes; IPv4
PROFINET IO ControllerNo
PROFINET IO DeviceNo
SIMATIC communicationYes; Only Server
Open IE communicationYes; Optionally also encrypted
Web serverYes
Media redundancyNo
Interface types
RJ 45 (Ethernet)
100 MbpsYes
AutonegotiationYes
AutocrossingYes
Industrial Ethernet status LEDYes
Protocols
PROFIsafeNo
Number of connections
Number of connections, max.256; via integrated interfaces of the CPU and connected CPs
Number of connections reserved for ES/HMI/web10
Number of connections via integrated interfaces128
Number of S7 routing paths16
Redundancy mode
PROFINET system redundancy (S2)Yes
PROFINET system redundancy (R1)No
Media redundancy
Media redundancyYes; only via 1st interface (X1)
MRPYes; MRP Automanager according to IEC 62439-2 Edition 2.0
MRP interconnection, supportedYes; as MRP ring node according to IEC 62439-2 Edition 3.0
MRPDNo
Switchover time on line break, typ.200 ms; PROFINET MRP
Number of stations in the ring, max.50; Only 16 are recommended, however
SIMATIC communication
PG/OP communicationYes; encryption with TLS V1.3 pre-selected
S7 routingYes
S7 communication, as serverYes
S7 communication, as clientNo
Open IE communication
TCP/IPYes
Data length, max.64 kbyte
several passive connections per port, supportedYes
ISO-on-TCP (RFC1006)Yes
Data length, max.64 kbyte
UDPYes
Data length, max.2 kbyte; 1 472 bytes for UDP broadcast
UDP multicastYes; max. 118 multicast circuits
DHCPNo
DNSYes
SNMPYes
DCPYes
LLDPYes
EncryptionYes; Optional
Web server
HTTPNo
HTTPSYes; standard pages
web APIYes
Number of sessions, max.100
number of simultaneous HTTP calls, max.4
HTTP request body, max.131 072 byte
OPC UA
Runtime license requiredYes; "Medium" license required per CPU
OPC UA ClientNo
OPC UA ServerYes; data access (read, write, subscribe), method call, custom address space, role-based access control
Application authenticationYes
Security policiesavailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss
User authentication"anonymous" or by user name & password
GDS support (certificate management)Yes
Number of sessions, max.24
Number of subscriptions per session, max.25
Sampling interval, min.250 ms
Publishing interval, min.250 ms
Number of server methods, max.500; max. 25 concurrently running jobs each for asynchronous instructions OPC_UA_ServerMethodPre and OPC_UA_ServerMethodPost
Number of inputs/outputs per server method, max.20
Number of monitored items, recommended max.2 000; for 1 s sampling interval and 1 s send interval
Number of server interfaces, max.10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace"
Number of nodes for user-defined server interfaces, max.30 000
Alarms and ConditionsNo
Further protocols
MODBUSYes; MODBUS TCP
S7 message functions
Number of login stations for message functions, max.64
number of subscriptions, max.500
number of tags/attributes for subscriptions, max.8 000
Program alarmsYes
Number of configurable program messages, max.10 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH
Number of loadable program messages in RUN, max.10 000
Number of simultaneously active program alarms
Number of program alarms1 000
Number of alarms for system diagnostics200
Test commissioning functions
Joint commission (Team Engineering)Yes; Parallel online access possible for up to 10 engineering systems
Status blockYes; up to 8 simultaneously
Single stepNo
Number of breakpoints8; Breakpoints are only supported in RUN-Solo status
ProfilingYes
Status/control
Status/control variableYes
VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Number of variables, max.
of which status variables, max.200; per job
of which control variables, max.200; per job
Forcing
ForcingYes
Forcing, variablesPeripheral inputs/outputs
Number of variables, max.200
Diagnostic buffer
presentYes
Number of entries, max.3 200
of which powerfail-proof500
Traces
Number of configurable Traces4
Memory size per trace, max.512 kbyte
Interrupts/diagnostics/status information
Diagnostics indication LED
RUN/STOP LEDYes
ERROR LEDYes
MAINT LEDYes
STOP ACTIVE LEDYes
Connection display LINK TX/RXYes
Supported technology objects
Motion ControlNo
Controller
PID_CompactYes; Universal PID controller with integrated optimization
PID_3StepYes; PID controller with integrated optimization for valves
PID-TempYes; PID controller with integrated optimization for temperature
Counting and measuringYes
Standards, approvals, certificates
Siemens Eco Profile (SEP)Siemens EcoTech
Ecological footprint
environmental product declarationYes
Global warming potential
global warming potential, (total) [CO2 eq]100 kg
global warming potential, (during production) [CO2 eq]25.8 kg
global warming potential, (during operation) [CO2 eq]75.2 kg
global warming potential, (after end of life cycle) [CO2 eq]-0.83 kg
Security
PROFINET Security Class1
signed firmware updateYes
Secure BootYes
securely removing dataYes
Ambient conditions
Ambient temperature during operation
horizontal installation, min.-30 °C; No condensation
horizontal installation, max.60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off
vertical installation, min.-30 °C; No condensation
vertical installation, max.40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off
Ambient temperature during storage/transportation
min.-40 °C
max.70 °C
Altitude during operation relating to sea level
Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Configuration
Programming
Programming language
LADYes
FBDYes
STLYes
SCLYes
CFCYes
GRAPHYes
Know-how protection
User program protection/password protectionYes
Copy protectionNo
Block protectionYes
Access protection
protection of confidential configuration dataYes
Password for displayYes
Protection level: Write protectionYes
Protection level: Read/write protectionYes
Protection level: Write protection for FailsafeNo
Protection level: Complete protectionYes
User administrationYes; device-wide and centralized
Number of users100
Number of groups100
Number of roles50
Cycle time monitoring
lower limitadjustable minimum cycle time
upper limitadjustable maximum cycle time
Dimensions
Width70 mm
Height147 mm
Depth129 mm
Weights
Weight, approx.456 g