0x5864:003 Stav inicializácie slave EtherCAT: Stav inicializácie slave 3 U16 - (Read only) - Lenze i950
0x5864:004 Stav inicializácie slave EtherCAT: Stav inicializácie slave 4 U16 - (Read only) - Lenze i950
0x5864:005 Stav inicializácie slave EtherCAT: Stav inicializácie slave 5 U16 - (Read only) - Lenze i950
0x5864:006 Stav inicializácie slave EtherCAT: Stav inicializácie slave 6 U16 - (Read only) - Lenze i950
0x5864:007 Stav inicializácie slave EtherCAT: Stav inicializácie slave 7 U16 - (Read only) - Lenze i950
0x5864:008 Stav inicializácie slave EtherCAT: Stav inicializácie slave 8 U16 - (Read only) - Lenze i950
0x5864:009 Stav inicializácie slave EtherCAT: Stav inicializácie slave 9 U16 - (Read only) - Lenze i950
0x5864:010 Stav inicializácie slave EtherCAT: Stav inicializácie slave 10 U16 - (Read only) - Lenze i950
0x5864:011 Stav inicializácie slave EtherCAT: Stav inicializácie slave 11 U16 - (Read only) - Lenze i950
0x5864:012 Stav inicializácie slave EtherCAT: Stav inicializácie slave 12 U16 - (Read only) - Lenze i950
0x5864:013 Stav inicializácie slave EtherCAT: Stav inicializácie slave 13 U16 - (Read only) - Lenze i950
0x5864:014 Stav inicializácie slave EtherCAT: Stav inicializácie slave 14 U16 - (Read only) - Lenze i950
0x5864:015 Stav inicializácie slave EtherCAT: Stav inicializácie slave 15 U16 - (Read only) - Lenze i950
0x5864:016 Stav inicializácie slave EtherCAT: Stav inicializácie slave 16 U16 - (Read only) - Lenze i950
0x5865:001 Stav zariadení slave EtherCAT: Stav zariadenia slave 1 U16 - (Read only) - Lenze i950
0x5865:002 Stav zariadení slave EtherCAT: Stav zariadenia slave 2 U16 - (Read only) - Lenze i950
0x5865:003 Stav zariadení slave EtherCAT: Stav zariadenia slave 3 U16 - (Read only) - Lenze i950
0x5865:004 Stav zariadení slave EtherCAT: Stav zariadenia slave 4 U16 - (Read only) - Lenze i950
0x5865:005 Stav zariadení slave EtherCAT: Stav zariadenia slave 5 U16 - (Read only) - Lenze i950
0x5865:006 Stav zariadení slave EtherCAT: Stav zariadenia slave 6 U16 - (Read only) - Lenze i950
0x5865:007 Stav zariadení slave EtherCAT: Stav zariadenia slave 7 U16 - (Read only) - Lenze i950
0x5865:008 Stav zariadení slave EtherCAT: Stav zariadenia slave 8 U16 - (Read only) - Lenze i950
0x5865:009 Stav zariadení slave EtherCAT: Stav zariadenia slave 9 U16 - (Read only) - Lenze i950
0x5865:010 Stav zariadení slave EtherCAT: Stav zariadenia slave 10 U16 - (Read only) - Lenze i950
0x5865:011 Stav zariadení slave EtherCAT: Stav zariadenia slave 11 U16 - (Read only) - Lenze i950
0x5865:012 Stav zariadení slave EtherCAT: Stav zariadenia slave 12 U16 - (Read only) - Lenze i950
0x5865:013 Stav zariadení slave EtherCAT: Stav zariadenia slave 13 U16 - (Read only) - Lenze i950
0x5865:014 Stav zariadení slave EtherCAT: Stav zariadenia slave 14 U16 - (Read only) - Lenze i950
0x5865:015 Stav zariadení slave EtherCAT: Stav zariadenia slave 15 U16 - (Read only) - Lenze i950
0x5865:016 Stav zariadení slave EtherCAT: Stav zariadenia slave 16 U16 - (Read only) - Lenze i950
0x603F Kód chyby U16 - (Read only) H Lenze i950, i550
0x6040 Riadiace slovo CiA U16 0x0000 H Lenze i950, i550
0x6041 Stavové slovo CiA U16 - (Read only) H Lenze i950, i550
0x6042 Žiadané otáčky I16 0 rpm - Lenze i950, i550
0x6043 Interné žiadané otáčky I16 x rpm (Read only) - Lenze i950, i550
0x6044 Skutočné otáčky I16 x rpm (Read only) - Lenze i950, i550
0x6046:001 Limity otáčok: Min. otáčky U32 0 rpm - Lenze i950, i550
0x6046:002 Limity otáčok: Max. otáčky U32 2147483647 rpm - Lenze i950, i550
0x6048:001 Rampa zrýchľovania: Zrýchlenie CiA: Delta otáčok U32 0 rpm - Lenze i950, i550
0x6048:002 Rampa zrýchľovania: Zrýchlenie CiA: Delta času U16 10 s - Lenze i950, i550
0x6049:001 Rampa spomaľovania: Spomalenie CiA: Delta otáčok U32 0 rpm - Lenze i950, i550
0x6049:002 Rampa spomaľovania: Spomalenie CiA: Delta času U16 10 s - Lenze i950, i550
0x604B:001 Faktor žiadanej hodnoty vl: Čitateľ faktora žiadanej hodnoty vl I16 1 - Lenze i950
0x604B:002 Faktor žiadanej hodnoty vl: Menovateľ faktora žiadanej hodnoty vl I16 1 - Lenze i950
0x604C:001 Faktor rozmeru vl: Čitateľ faktora rozmeru vl I32 1 - Lenze i950
0x604C:002 Faktor rozmeru vl: Menovateľ faktora rozmeru vl I32 1 - Lenze i950
0x605A CiA: Režim rýchleho zastavenia I16 Rampa > zapnutie zablokované [2] - Lenze i950, i550
0x605B Kód voľby vypnutia I16 Vypnúť funkciu pohonu [0] - Lenze i950, i550
0x605E CiA: Reakcia na menšie poruchy I16 Rozšírené rýchle zastavenie [-2] - Lenze i950
0x6060 CiA: Prevádzkový režim I8 Bez výberu [0] - Lenze i950, i550