6AG1526-2BF00-2AB0

6AG1526-2BF00-2AB0

SIPLUS S7-1500 F-DQ 8x24VDC/2A na bazie 6ES7526-2BF00-0AB0 z powłoką ochronną, -30…+60 °C, moduł wyjść cyfrowych F, szerokość 35 mm; do PL e (ISO 13849-1)/SIL3 (IEC 61508).

Kategoria produktu
Moduły cyfrowe
Producent
SIEMENS
Seria produktów
S7-1500
General information
Product type designationF-DQ 8x24VDC/2A PPM
Firmware version
FW update possibleYes
based on6ES7526-2BF00-0AB0
Product function
I&M dataYes; I&M0 to I&M3
Engineering with
STEP 7 TIA Portal configurable/integrated from versionsee entry ID: 109746275
Operating mode
DQYes
MSONo
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
power supply according to NEC Class 2 requiredNo
Input current
Current consumption (rated value)110 mA; without load
Current consumption, max.130 mA; without load
Output voltage
Rated value (DC)24 V
Power
Power consumption from the backplane bus0.8 W
Power loss
Power loss, typ.11 W
Address area
Address space per module
Inputs6 byte; S7-300/400F CPU, 5 byte
Outputs6 byte; S7-300/400F CPU, 5 byte
Hardware configuration
Automatic encodingYes
Electronic coding element type FYes
Digital outputs
Number of digital outputs8
Current-sinkingYes
Current-sourcingYes
Short-circuit protectionYes
Open-circuit detectionYes
Response threshold, typ.8 mA
Overload protectionYes
Response threshold, typ.2.9 A
Limitation of inductive shutdown voltage toPM-switching: -24 V + (-47 V), PP-switching: -24 V
Controlling a digital inputYes; digital output, according to IEC 61131-2, type 2
Switching capacity of the outputs
with resistive load, max.2 A
on lamp load, max.10 W
Load resistance range
lower limit12 Ω
upper limit2 000 Ω
Output voltage
for signal "1", min.24 V; L+ (-0.5 V)
Output current
for signal "1" rated value2 A
for signal "0" residual current, max.0.5 mA; Current-sourcing, or current sourcing and sinking switches individually, current sinking: max. 1 mA
Switching frequency
with resistive load, max.30 Hz
with inductive load, max.0.1 Hz
on lamp load, max.10 Hz
Total current of the outputs
Current per channel, max.2 A
Total current of the outputs (per module)
horizontal installation
up to 40 °C, max.16 A
up to 60 °C, max.8 A
vertical installation
up to 40 °C, max.8 A
Cable length
shielded, max.1 000 m
unshielded, max.500 m
Interrupts/diagnostics/status information
Diagnostics functionYes
Substitute values connectableNo
Alarms
Diagnostic alarmYes
Diagnoses
Monitoring the supply voltageYes
Wire breakYes
Short-circuitYes
Group errorYes
Diagnostics indication LED
RUN LEDYes; green LED
ERROR LEDYes; red LED
Monitoring of the supply voltage (PWR-LED)Yes
Channel status displayYes; green LED
for channel diagnosticsYes; red LED
for module diagnosticsYes; red LED
Potential separation
Potential separation channels
between the channelsNo
between the channels and backplane busYes
Isolation
Isolation tested with707 V DC (type test)
Standards, approvals, certificates
Suitable for safety functionsYes
Highest safety class achievable in safety mode
Performance level according to ISO 13849-1PLe
SIL acc. to IEC 61508SIL 3
Probability of failure (for service life of 20 years and repair time of 100 hours)
Low demand mode: PFDavg in accordance with SIL3< 6.00E-05
High demand/continuous mode: PFH in accordance with SIL3< 2.00E-09 1/h
Ambient conditions
Ambient temperature during operation
horizontal installation, min.-30 °C; = Tmin (incl. condensation/frost)
horizontal installation, max.60 °C; = Tmax
vertical installation, min.-30 °C; = Tmin
vertical installation, max.40 °C; = Tmax
Altitude during operation relating to sea level
Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Relative humidity
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
Resistance
Coolants and lubricants
Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Use in stationary industrial systems
to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Use on ships/at sea
to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
Usage in industrial process technology
Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A
Dimensions
Width35 mm
Height147 mm
Depth129 mm
Weights
Weight, approx.300 g
Approvals / Certificates