6AG1513-1AM03-2AB0
SIPLUS S7-1500 CPU 1513-1 PN na bazie 6ES7513-1AM03-0AB0 z powłoką ochronną -40...+60 °C . jednostka centralna z pamięcią programu 600 KB i pamięcią danych 2.5 MB, 1. interfejs: PROFINET IRT ze switchem 2-portowym, wydajność bitowa 25 ns, wymagana karta SIMATIC Memory Card.
Kategoria produktu
CPUProducent
SIEMENSSeria produktów
S7-1500| General information | |
|---|---|
| Product type designation | CPU 1513-1 PN |
| Firmware version | |
| FW update possible | Yes |
| based on | 6ES7513-1AM03-0AB0 |
| Product function | |
| I&M data | Yes; I&M0 to I&M3 |
| Isochronous mode | Yes; Distributed and central; with minimum OB 6x cycle of 500 µs (distributed) and 1 ms (central) |
| SysLog | Yes |
| Engineering with | |
| STEP 7 TIA Portal configurable/integrated from version | see entry ID: 109746275 |
| Configuration control | |
| via dataset | Yes |
| Display | |
| Screen diagonal [cm] | 3.45 cm |
| Control elements | |
| Number of keys | 8 |
| Mode buttons | 2 |
| Supply voltage | |
| Rated value (DC) | 24 V |
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
| Mains buffering | |
| Mains/voltage failure stored energy time | 5 ms |
| Repeat rate, min. | 1/s |
| Input current | |
| Current consumption (rated value) | 0.56 A |
| Current consumption, max. | 0.9 A |
| Inrush current, max. | 1.15 A; Rated value |
| I²t | 0.6 A²·s |
| Power | |
| Infeed power to the backplane bus | 10 W |
| Power consumption from the backplane bus (balanced) | 5.5 W |
| Power loss | |
| Power loss, typ. | 3.4 W |
| Storage | |
| Number of slots for SIMATIC memory card | 1 |
| SIMATIC memory card required | Yes |
| Work memory | |
| integrated (for program) | 600 kbyte |
| integrated (for data) | 2.5 Mbyte |
| Load memory | |
| Plug-in (SIMATIC Memory Card), max. | 32 Gbyte |
| Backup | |
| maintenance-free | Yes |
| CPU processing times | |
| for bit operations, typ. | 25 ns |
| for word operations, typ. | 32 ns |
| for fixed point arithmetic, typ. | 42 ns |
| for floating point arithmetic, typ. | 170 ns |
| CPU-blocks | |
| Number of elements (total) | 4 000; Blocks (OB, FB, FC, DB) and UDTs |
| DB | |
| Number range | 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999 |
| Size, max. | 2.5 Mbyte; For DBs with absolute addressing, the max. size is 64 KB |
| FB | |
| Number range | 0 ... 65 535 |
| Size, max. | 600 kbyte |
| FC | |
| Number range | 0 ... 65 535 |
| Size, max. | 600 kbyte |
| OB | |
| Size, max. | 600 kbyte |
| Number of free cycle OBs | 100 |
| Number of time alarm OBs | 20 |
| Number of delay alarm OBs | 20 |
| Number of cyclic interrupt OBs | 20; With minimum OB 3x cycle of 250 µs |
| Number of process alarm OBs | 50 |
| Number of DPV1 alarm OBs | 3 |
| Number of isochronous mode OBs | 2 |
| Number of technology synchronous alarm OBs | 2 |
| Number of startup OBs | 100 |
| Number of asynchronous error OBs | 4 |
| Number of synchronous error OBs | 2 |
| Number of diagnostic alarm OBs | 1 |
| Nesting depth | |
| per priority class | 24 |
| Counters, timers and their retentivity | |
| S7 counter | |
| Number | 2 048 |
| Retentivity | |
| can be set | Yes |
| IEC counter | |
| Number | Any (only limited by the main memory) |
| Retentivity | |
| can be set | Yes |
| S7 timer | |
| Number | 2 048 |
| Retentivity | |
| can be set | Yes |
| IEC timer | |
| Number | Any (only limited by the main memory) |
| Retentivity | |
| can be set | Yes |
| Data areas and their retentivity | |
| Retentive data area (incl. timers, counters, flags), max. | 256 kbyte; in total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 216 KB |
| Extended retentive data area (incl. timers, counters, flags), max. | 2.5 Mbyte; When using PS 6 0W 24/48/60 V DC HF |
| Flag | |
| Size, max. | 16 kbyte |
| Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte |
| Data blocks | |
| Retentivity adjustable | Yes |
| Retentivity preset | No |
| Local data | |
| per priority class, max. | 64 kbyte; max. 16 KB per block |
| Address area | |
| Number of IO modules | 2 048; max. number of modules / submodules |
| I/O address area | |
| Inputs | 32 kbyte; All inputs are in the process image |
| Outputs | 32 kbyte; All outputs are in the process image |
| per integrated IO subsystem | |
| Inputs (volume) | 8 kbyte |
| Outputs (volume) | 8 kbyte |
| per CM/CP | |
| Inputs (volume) | 8 kbyte |
| Outputs (volume) | 8 kbyte |
| Subprocess images | |
| Number of subprocess images, max. | 32 |
| Hardware configuration | |
| Number of distributed IO systems | 32; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link) |
| Number of DP masters | |
| via CM | 6; A maximum of 6 CMs (PROFINET + PROFIBUS) can be inserted in total |
| Number of IO Controllers | |
| Integrated | 1 |
| via CM | 6; A maximum of 6 CMs (PROFINET + PROFIBUS) can be inserted in total |
| Rack | |
| Modules per rack, max. | 32; CPU + 31 modules |
| Number of lines, max. | 1 |
| PtP CM | |
| Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots |
| Time of day | |
| Clock | |
| Type | Hardware clock |
| Backup time | 6 wk; At 40 °C ambient temperature, typically |
| Deviation per day, max. | 10 s; Typ.: 2 s |
| Operating hours counter | |
| Number | 16 |
| Clock synchronization | |
| supported | Yes |
| to DP, master | Yes; via PROFIBUS CM / CP |
| on DP, device | Yes; via PROFIBUS CM / CP |
| in AS, master | Yes |
| in AS, device | Yes |
| on Ethernet via NTP | Yes |
| Interfaces | |
| Number of PROFINET interfaces | 1 |
| 1. Interface | |
| Interface types | |
| RJ 45 (Ethernet) | Yes; X1 |
| Number of ports | 2 |
| integrated switch | Yes |
| Protocols | |
| IP protocol | Yes; IPv4 |
| PROFINET IO Controller | Yes |
| PROFINET IO device | Yes |
| SIMATIC communication | Yes |
| Open IE communication | Yes; Optionally also encrypted |
| Web server | Yes |
| Media redundancy | Yes |
| PROFINET IO Controller | |
| Services | |
| Isochronous mode | Yes |
| Direct data exchange | Yes; Requirement: IRT and isochronous mode (MRPD optional) |
| IRT | Yes |
| Dynamic Frame Packing (DFP) | Yes |
| PROFIenergy | Yes; per user program |
| Prioritized startup | Yes; Max. 32 PROFINET devices |
| Number of connectable IO Devices, max. | 128; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET |
| Of which IO devices with IRT, max. | 64 |
| Number of connectable IO Devices for RT, max. | 128 |
| of which in line, max. | 128 |
| Number of IO Devices that can be simultaneously activated/deactivated, max. | 8; in total across all interfaces |
| Number of IO Devices per tool, max. | 8 |
| Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data |
| PROFINET Security Class | 1 |
| Update time for IRT | |
| for send cycle of 250 µs | 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 500 µs of the isochronous OB is decisive |
| for send cycle of 500 µs | 500 µs to 8 ms |
| for send cycle of 1 ms | 1 ms to 16 ms |
| for send cycle of 2 ms | 2 ms to 32 ms |
| for send cycle of 4 ms | 4 ms to 64 ms |
| With IRT and parameterization of "odd" send cycles | Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs) |
| Update time for RT | |
| for send cycle of 250 µs | 250 µs to 128 ms |
| for send cycle of 500 µs | 500 µs to 256 ms |
| for send cycle of 1 ms | 1 ms to 512 ms |
| for send cycle of 2 ms | 2 ms to 512 ms |
| for send cycle of 4 ms | 4 ms to 512 ms |
| PROFINET IO Device | |
| Services | |
| Isochronous mode | No |
| IRT | Yes |
| Dynamic Frame Packing (DFP) | No |
| PROFIenergy | Yes; per user program |
| Prioritized startup | Yes |
| Shared device | Yes |
| Number of IO Controllers with shared device, max. | 4 |
| activation/deactivation of I-devices | Yes; per user program |
| Asset management record | Yes; per user program |
| PROFINET Security Class | SNMP Configuration and DCP Read Only |
| Interface types | |
| RJ 45 (Ethernet) | |
| 100 Mbps | Yes |
| Autonegotiation | Yes |
| Autocrossing | Yes |
| Industrial Ethernet status LED | Yes |
| Protocols | |
| PROFIsafe | No |
| Number of connections | |
| Number of connections, max. | 128; via integrated interfaces of the CPU and connected CPs / CMs |
| Number of connections reserved for ES/HMI/web | 10 |
| Number of connections via integrated interfaces | 88 |
| Number of S7 routing paths | 16 |
| Redundancy mode | |
| PROFINET system redundancy (S2) | No |
| PROFINET system redundancy (R1) | No |
| H-Sync forwarding | Yes |
| Media redundancy | |
| Media redundancy | only via 1st interface (X1) |
| MRP | Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client |
| MRP interconnection, supported | Yes; as MRP ring node according to IEC 62439-2 Edition 3.0 |
| MRPD | Yes; Requirement: IRT |
| Switchover time on line break, typ. | 200 ms; For MRP, bumpless for MRPD |
| Number of stations in the ring, max. | 50 |
| SIMATIC communication | |
| PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
| S7 routing | Yes |
| Data record routing | Yes |
| S7 communication, as server | Yes |
| S7 communication, as client | Yes |
| User data per job, max. | See online help (S7 communication, user data size) |
| Open IE communication | |
| TCP/IP | Yes |
| Data length, max. | 64 kbyte |
| several passive connections per port, supported | Yes |
| ISO-on-TCP (RFC1006) | Yes |
| Data length, max. | 64 kbyte |
| UDP | Yes |
| Data length, max. | 2 kbyte; 1 472 bytes for UDP broadcast |
| UDP multicast | Yes; max. 78 multicast circuits |
| DHCP | Yes |
| DNS | Yes |
| SNMP | Yes |
| DCP | Yes |
| LLDP | Yes |
| encryption | Yes; Optional |
| Web server | |
| HTTP | Yes; Standard and user pages |
| HTTPS | Yes; Standard and user pages |
| web API | |
| Number of sessions, max. | 50 |
| number of simultaneous HTTP calls, max. | 4 |
| HTTP request body, max. | 131 072 byte |
| OPC UA | |
| Runtime license required | Yes; "Small" license required |
| OPC UA Client | Yes; Data Access (registered Read/Write), Method Call |
| Application authentication | Yes |
| Security policies | Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 |
| User authentication | "anonymous" or by user name & password |
| Number of connections, max. | 4 |
| Number of nodes of the client interfaces, recommended max. | 1 000 |
| Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max. | 300 |
| Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max. | 20 |
| Number of elements for one call of OPC_UA_MethodGetHandleList, max. | 100 |
| Number of simultaneous calls of the client instructions for session management, per connection, max. | 1 |
| Number of simultaneous calls of the client instructions for data access, per connection, max. | 5 |
| Number of registerable nodes, max. | 5 000 |
| Number of registerable method calls of OPC_UA_MethodCall, max. | 100 |
| Number of inputs/outputs when calling OPC_UA_MethodCall, max. | 20 |
| OPC UA Server | Yes; Data Access (Read, Write, Subscribe), Method Call, Alarms & Condition (A&C), Custom Address Space |
| Application authentication | Yes |
| Security policies | available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss |
| User authentication | "anonymous" or by user name & password |
| GDS support (certificate management) | Yes |
| Number of sessions, max. | 32 |
| Number of accessible variables, max. | 50 000 |
| Number of registerable nodes, max. | 10 000 |
| Number of subscriptions per session, max. | 50 |
| Sampling interval, min. | 100 ms |
| Publishing interval, min. | 200 ms |
| Number of server methods, max. | 20 |
| Number of inputs/outputs per server method, max. | 20 |
| Number of monitored items, recommended max. | 4 000; for 1 s sampling interval and 1 s send interval |
| Number of server interfaces, max. | 10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace" |
| Number of nodes for user-defined server interfaces, max. | 15 000 |
| Alarms and Conditions | Yes |
| Number of program alarms | 100 |
| Number of alarms for system diagnostics | 50 |
| Further protocols | |
| MODBUS | Yes; MODBUS TCP |
| S7 message functions | |
| Number of login stations for message functions, max. | 32 |
| Program alarms | Yes |
| Number of configurable program messages, max. | 5 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH |
| Number of loadable program messages in RUN, max. | 2 500 |
| Number of simultaneously active program alarms | |
| Number of program alarms | 600 |
| Number of alarms for system diagnostics | 100 |
| Number of alarms for motion technology objects | 160 |
| Test commissioning functions | |
| Joint commission (Team Engineering) | Yes; Parallel online access possible for up to 5 engineering systems |
| Status block | Yes; Up to 8 simultaneously (in total across all ES clients) |
| Single step | No |
| Number of breakpoints | 8 |
| Profiling | Yes |
| Status/control | |
| Status/control variable | Yes |
| Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
| Number of variables, max. | |
| of which status variables, max. | 200; per job |
| of which control variables, max. | 200; per job |
| Forcing | |
| Forcing | Yes |
| Forcing, variables | Peripheral inputs/outputs |
| Number of variables, max. | 200 |
| Diagnostic buffer | |
| present | Yes |
| Number of entries, max. | 1 000 |
| of which powerfail-proof | 500 |
| Traces | |
| Number of configurable Traces | 4 |
| Memory size per trace, max. | 512 kbyte |
| Interrupts/diagnostics/status information | |
| Diagnostics indication LED | |
| RUN/STOP LED | Yes |
| ERROR LED | Yes |
| MAINT LED | Yes |
| STOP ACTIVE LED | Yes |
| Connection display LINK TX/RX | Yes |
| Supported technology objects | |
| Motion Control | Yes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool |
| Number of available Motion Control resources for technology objects | 1 120 |
| Required Motion Control resources | |
| per speed-controlled axis | 40 |
| per positioning axis | 80 |
| per synchronous axis | 160 |
| per external encoder | 80 |
| per output cam | 20 |
| per cam track | 160 |
| per probe | 40 |
| Positioning axis | |
| Number of positioning axes at motion control cycle of 4 ms (typical value) | 11 |
| Number of positioning axes at motion control cycle of 8 ms (typical value) | 14 |
| Controller | |
| PID_Compact | Yes; Universal PID controller with integrated optimization |
| PID_3Step | Yes; PID controller with integrated optimization for valves |
| PID-Temp | Yes; PID controller with integrated optimization for temperature |
| Counting and measuring | |
| High-speed counter | Yes |
| Standards, approvals, certificates | |
| Ecological footprint | |
| environmental product declaration | Yes |
| Global warming potential | |
| global warming potential, (total) [CO2 eq] | 80.1 kg |
| global warming potential, (during production) [CO2 eq] | 23.8 kg |
| global warming potential, (during operation) [CO2 eq] | 57.4 kg |
| global warming potential, (after end of life cycle) [CO2 eq] | -1.29 kg |
| Security | |
| PROFINET Security Class | 1 |
| Ambient conditions | |
| Ambient temperature during operation | |
| horizontal installation, min. | -40 °C; = Tmin (incl. condensation/frost) |
| horizontal installation, max. | 60 °C; = Tmax; display: 50 °C, the display is switched off at an operating temperature of typically 50 °C |
| vertical installation, min. | -40 °C; = Tmin |
| vertical installation, max. | 40 °C; = Tmax; display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off |
| Ambient temperature during storage/transportation | |
| min. | -40 °C |
| max. | 70 °C |
| Altitude during operation relating to sea level | |
| Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
| Relative humidity | |
| With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation |
| Resistance | |
| Coolants and lubricants | |
| Resistant to commercially available coolants and lubricants | Yes; Incl. diesel and oil droplets in the air |
| Use in stationary industrial systems | |
| to biologically active substances according to EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
| to chemically active substances according to EN 60721-3-3 | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
| to mechanically active substances according to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust, * |
| Use on ships/at sea | |
| to biologically active substances according to EN 60721-3-6 | Yes; Class 6B2 mold, fungal and dry rot spores (excluding fauna) |
| to chemically active substances according to EN 60721-3-6 | Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
| to mechanically active substances according to EN 60721-3-6 | Yes; Class 6S3 incl. sand, dust; * |
| Usage in industrial process technology | |
| Against chemically active substances acc. to EN 60654-4 | Yes; Class 3 (excluding trichlorethylene) |
| Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04 | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) |
| Remark | |
| Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 | * The supplied plug covers must remain in place over the unused interfaces during operation! |
| Conformal coating | |
| Coatings for printed circuit board assemblies acc. to EN 61086 | Yes; Class 2 for high reliability |
| Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection |
| Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life |
| Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A | Yes; Conformal coating, Class A |
| Configuration | |
| Programming | |
| Programming language | |
| LAD | Yes |
| FBD | Yes |
| STL | Yes |
| SCL | Yes |
| CFC | Yes |
| GRAPH | Yes |
| Know-how protection | |
| User program protection/password protection | Yes |
| Copy protection | Yes |
| Block protection | Yes |
| Access protection | |
| protection of confidential configuration data | Yes |
| Password for display | Yes |
| Protection level: Write protection | Yes |
| Protection level: Read/write protection | Yes |
| Protection level: Write protection for Failsafe | No |
| Protection level: Complete protection | Yes |
| User administration | Yes; device-wide |
| Cycle time monitoring | |
| lower limit | adjustable minimum cycle time |
| upper limit | adjustable maximum cycle time |
| Dimensions | |
| Width | 35 mm |
| Height | 147 mm |
| Depth | 129 mm |
| Weights | |
| Weight, approx. | 336 g |
| Approvals / Certificates | |