| Title | Parameter | Display Code | Data type | Default setting | Fieldbus | Manufacturer | Product category | Operations |
|---|---|---|---|---|---|---|---|---|
| 0x10F3:008 | Diagnosis History: Diagnosis message 2 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:009 | Diagnosis History: Diagnosis message 3 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:010 | Diagnosis History: Diagnosis message 4 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:011 | Diagnosis History: Diagnosis message 5 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:012 | Diagnosis History: Diagnosis message 6 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:013 | Diagnosis History: Diagnosis message 7 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:014 | Diagnosis History: Diagnosis message 8 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:015 | Diagnosis History: Diagnosis message 9 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:016 | Diagnosis History: Diagnosis message 10 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:017 | Diagnosis History: Diagnosis message 11 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:018 | Diagnosis History: Diagnosis message 12 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:019 | Diagnosis History: Diagnosis message 13 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:020 | Diagnosis History: Diagnosis message 14 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:021 | Diagnosis History: Diagnosis message 15 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:022 | Diagnosis History: Diagnosis message 16 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:023 | Diagnosis History: Diagnosis message 17 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:024 | Diagnosis History: Diagnosis message 18 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:025 | Diagnosis History: Diagnosis message 19 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:026 | Diagnosis History: Diagnosis message 20 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:027 | Diagnosis History: Diagnosis message 21 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:028 | Diagnosis History: Diagnosis message 22 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:029 | Diagnosis History: Diagnosis message 23 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:030 | Diagnosis History: Diagnosis message 24 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:031 | Diagnosis History: Diagnosis message 25 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:032 | Diagnosis History: Diagnosis message 26 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:033 | Diagnosis History: Diagnosis message 27 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:034 | Diagnosis History: Diagnosis message 28 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:035 | Diagnosis History: Diagnosis message 29 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:036 | Diagnosis History: Diagnosis message 30 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x10F3:037 | Diagnosis History: Diagnosis message 31 | OCTET[19] | - (Read only) | EtherCAT | Lenze | i550 | ||
| 0x1200:000 | SDO1 server parameter: Highest sub-index supported | U8 | - (Read only) | CANopen | Lenze | i550 | ||
| 0x1200:001 | SDO1 server parameter: COB-ID client > server (rx) | U32 | - (Read only) | CANopen | Lenze | i550 | ||
| 0x1200:002 | SDO1 server parameter: COB-ID server > client (tx) | U32 | - (Read only) | CANopen | Lenze | i550 | ||
| 0x1201:000 | SDO2 server parameter: Highest sub-index supported | U8 | - (Read only) | CANopen | Lenze | i550 | ||
| 0x1201:001 | SDO2 server parameter: COB-ID client > server (rx) | U32 | 0x80000640 | CANopen | Lenze | i550 | ||
| 0x1201:002 | SDO2 server parameter: COB-ID server > client (tx) | U32 | 0x800005C0 | CANopen | Lenze | i550 | ||
| 0x1201:003 | SDO2 server parameter: Node-ID of the SDO client | U8 | 0 | CANopen | Lenze | i550 | ||
| 0x1300 | SDO_SequLayerTimeout_U32 | U32 | 15000 ms | POWERLINK | Lenze | i550 | ||
| 0x1301 | SDO_CmdLayerTimeout_U32 | U32 | 30000 ms | POWERLINK | Lenze | i550 | ||
| 0x1400:000 | RPDO1 communication parameter: Highest sub- index supported | U8 | - (Read only) | CANopen | Lenze | i550 | ||
| 0x1400:001 | PDO_RxCommParam_00h_REC: NodeID_U8 | U8 | 0 | POWERLINK | Lenze | i550 | ||
| 0x1400:001 | RPDO1 communication parameter: COB-ID | P540.01 | U32 | 0x00000200 | CANopen | Lenze | i550 | |
| 0x1400:002 | RPDO1 communication parameter: Transmission type | P540.02 | U8 | 255 | CANopen | Lenze | i550 | |
| 0x1400:002 | PDO_RxCommParam_00h_REC: MappingVersion_U8 | U8 | - (Read only) | POWERLINK | Lenze | i550 | ||
| 0x1400:005 | RPDO1 communication parameter: Event timer | P540.05 | U16 | 100 ms | CANopen | Lenze | i550 | |
| 0x1401:001 | RPDO2 communication parameter: COB-ID | P541.01 | U32 | 0x80000300 | CANopen | Lenze | i550 | |
| 0x1401:002 | RPDO2 communication parameter: Transmission type | P541.02 | U8 | 255 | CANopen | Lenze | i550 | |
| 0x1401:005 | RPDO2 communication parameter: Event timer | P541.05 | U16 | 100 ms | CANopen | Lenze | i550 | |
| 0x1402:001 | RPDO3 communication parameter: COB-ID | P542.01 | U32 | 0x80000400 | CANopen | Lenze | i550 | |
| 0x1402:002 | RPDO3 communication parameter: Transmission type | P542.02 | U8 | 255 | CANopen | Lenze | i550 |