Title Parameter Display Code Data type Default setting Attributes Fieldbus Manufacturer Product category Operations
0x24E8:007 Network output data: Output data 7 U32 - (Read only) - Lenze i950
0x24E8:008 Network output data: Output data 8 U32 - (Read only) - Lenze i950
0x24E8:009 Network output data: Output data 9 U32 - (Read only) - Lenze i950
0x24E8:010 Network output data: Output data 10 U32 - (Read only) - Lenze i950
0x24E8:011 Network output data: Output data 11 U32 - (Read only) - Lenze i950
0x24E8:012 Network output data: Output data 12 U32 - (Read only) - Lenze i950
0x24E8:013 Network output data: Output data 13 U32 - (Read only) - Lenze i950
0x24E8:014 Network output data: Output data 14 U32 - (Read only) - Lenze i950
0x24E8:015 Network output data: Output data 15 U32 - (Read only) - Lenze i950
0x24E8:016 Network output data: Output data 16 U32 - (Read only) - Lenze i950
0x2500 Touch probe filter time U16 0 - Lenze i950
0x2539:001 Hardware diagnostics: External supply voltage U16 x.x V (Read only) - Lenze i950
0x2539:002 Hardware diagnostics: Control board temperature I16 x.x °C (Read only) - Lenze i950
0x2540:001 P208.01 Lenze i550
0x2540:001 Mains settings: Rated mains voltage U8 400 Veff [1] - Lenze i950, i550
0x2540:002 Mains settings: Undervoltage warning threshold U16 430 V - Lenze i950, i550
0x2540:003 Mains settings: Undervoltage error threshold U16 x V (Read only) - Lenze i950, i550
0x2540:004 Mains settings: Undervoltage reset threshold U16 x V (Read only) - Lenze i950, i550
0x2540:005 Mains settings: Overvoltage warning threshold U16 795 V - Lenze i950, i550
0x2540:006 Mains settings: Overvoltage error threshold U16 x V (Read only) - Lenze i950, i550
0x2540:006 P208.06 Lenze i550
0x2540:007 Mains settings: Overvoltage reset threshold U16 x V (Read only) - Lenze i950, i550
0x2540:008 Mains settings: DC link voltage critical U8 - (Read only) - Lenze i950
0x2541:001 P706.01 Lenze i550
0x2541:002 Brake energy management: Active threshold P706.02 U16 x V (Read only) general Lenze i550
0x2541:003 Brake energy management: Reduced threshold U16 0 V - Lenze i950, i550
0x2541:004 Brake energy management: Additional frequency P706.04 U16 0.0 Hz general Lenze i550
0x2541:005 Brake energy management: Deceleration override time P706.05 U16 2.0 s general Lenze i550
0x2541:006 Brake energy management: Brake resistor response P706.06 U8 Off: disable / Off: error [0] general Lenze i550
0x2550:001 Brake resistor: Minimum resistance U16 x.x Ω (Read only) - Lenze i950
0x2550:002 Brake resistor: Resistance value U16 180.0 Ω - Lenze i950, i550
0x2550:003 Brake resistor: Rated power U32 5600 W - Lenze i950, i550
0x2550:004 Brake resistor: Maximum thermal load U32 485 kWs - Lenze i950, i550
0x2550:006 Brake resistor: Reference resistance U8 Minimum resistance [0] - Lenze i950
0x2550:007 Brake resistor: Thermal load U16 x.x % (Read only) - Lenze i950, i550
0x2550:008 Brake resistor: Warning threshold U16 90.0 % - Lenze i950, i550
0x2550:009 Brake resistor: Error threshold P707.09 U16 100.0 % general Lenze i550
0x2550:010 Brake resistor: Response to warning U8 Warning [2] - Lenze i950, i550
0x2550:011 Brake resistor: Response to error U8 No response [0] - Lenze i950, i550
0x2552:002 Parameter access monitoring: Keep alive register P595.02 U16 0 general Lenze i550
0x2552:003 Parameter access monitoring: Time-out time P595.03 U16 10.0 s general Lenze i550
0x2552:004 Parameter access monitoring: Response P595.04 U8 No response [0] general Lenze i550
0x2552:005 Parameter access monitoring: Action P595.05 U8 No action [0] general Lenze i550
0x2552:006 Parameter access monitoring: Parameter Access Monitoring-Status P595.06 U16 - (Read only) general Lenze i550
0x2552:007 Parameter access monitoring: WLAN reset time-out time P595.07 U16 0 s general Lenze i550
0x2552:008 Parameter access monitoring: Mapped parameter IDX 0x400B0100 Lenze i550
0x2552:009 Parameter access monitoring: Value to be written P595.09 U32 0 Lenze i550
0x2552:010 Parameter access monitoring: Write status P595.10 U8 - (Read only) Lenze i550
0x2580:001 Distributed Clocks: Real time status U8 - (Read only) - Lenze i950
0x2580:002 Distributed Clocks: First setting time U64 x ns (Read only) T Lenze i950