Parameters

Filters
Title Parameter Display Code Data type Default setting Attributes Fieldbus Manufacturer Product category Operations
0x23B0 Modbus TCP communication P508.00 U8 No action/no error [0] Modbus TCP/IP Lenze i550
0x23B1:001 Modbus -TCP/IP settings: IP address P510.01 U32 192.168.124.16 Modbus TCP/IP Lenze i550
0x23B1:002 Modbus -TCP/IP settings: Subnet P510.02 U32 255.255.255.0 Modbus TCP/IP Lenze i550
0x23B1:003 Modbus -TCP/IP settings: Gateway P510.03 U32 0.0.0.0 Modbus TCP/IP Lenze i550
0x23B1:005 Modbus -TCP/IP settings: IP configuration P510.05 U8 Stored IP [0] Modbus TCP/IP Lenze i550
0x23B1:006 Modbus -TCP/IP settings: Time-to-live value (TTL) P510.06 U8 32 Modbus TCP/IP Lenze i550
0x23B1:010 Modbus -TCP/IP settings: Ethernet time-out P510.10 U16 10 s Modbus TCP/IP Lenze i550
0x23B1:011 Modbus -TCP/IP settings: Secondary port P510.11 U16 502 Modbus TCP/IP Lenze i550
0x23B2:001 Active Modbus TCP settings: Active IP address P511.01 U32 - (Read only) Modbus TCP/IP Lenze i550
0x23B2:002 Active Modbus TCP settings: Active subnet P511.02 U32 - (Read only) Modbus TCP/IP Lenze i550
0x23B2:003 Active Modbus TCP settings: Active gateway P511.03 U32 - (Read only) Modbus TCP/IP Lenze i550
0x23B2:005 Active Modbus TCP settings: MAC address P511.05 OCTET[6] - (Read only) Modbus TCP/IP Lenze i550
0x23B3 Switch position P509.00 U8 - (Read only) Modbus TCP/IP Lenze i550
0x23B4:001 Port settings: Port 1 P512.01 U16 Auto-Negotiation [0] Modbus TCP/IP Lenze i550
0x23B4:002 Port settings: Port 2 P512.02 U16 Auto-Negotiation [0] Modbus TCP/IP Lenze i550
0x23B5:001 Active port settings: Port 1 P513.01 U16 - (Read only) Modbus TCP/IP Lenze i550
0x23B5:002 Active port settings: Port 2 P513.02 U16 - (Read only) Modbus TCP/IP Lenze i550
0x23B6:001 Time-out monitoring: Time-out time P514.01 U16 2.0 s Modbus TCP/IP Lenze i550
0x23B6:002 Time-out monitoring: Keep alive time-out time P514.02 U16 2.0 s Modbus TCP/IP Lenze i550
0x23B6:005 Time-out monitoring: Keep alive register P514.05 U16 0 Modbus TCP/IP Lenze i550
0x23B8 Modbus TCP module status P516.00 U16 - (Read only) Modbus TCP/IP Lenze i550
0x23B9 Modbus TCP/IP network status P517.00 U16 - (Read only) Modbus TCP/IP Lenze i550
0x23BA:001 Modbus TCP statistics: Messages received P580.01 U32 - (Read only) Modbus TCP/IP Lenze i550
0x23BA:002 Modbus TCP statistics: Valid messages received P580.02 U32 - (Read only) Modbus TCP/IP Lenze i550
0x23BA:003 Modbus TCP statistics: Messages with exceptions P580.03 U32 - (Read only) Modbus TCP/IP Lenze i550
0x23BA:005 Modbus TCP statistics: Messages sent P580.05 U32 - (Read only) Modbus TCP/IP Lenze i550
0x23BB:001 ... 0x23BB:024 Modbus TCP/IP parameter mapping: Parameter 1 ... Parameter 24 P530.01 ... 24 IDX 0x00000000 Modbus TCP/IP Lenze i550
0x23BC:001 ... 0x23BC:024 Register assignment: Register 1 ... Register 24 P531.01 ... 24 U16 - (Read only) Modbus TCP/IP Lenze i550
0x23BD Verification code P532.00 U16 - (Read only) Modbus TCP/IP Lenze i550
0x23BE:001 Modbus TCP/IP diagnostics of last Rx/Tx data: Receive offset P585.01 U8 0 Modbus TCP/IP Lenze i550
0x23BE:002 Modbus TCP/IP diagnostics of last Rx/Tx data: Last Rx message P585.02 OCTET[64] - (Read only) Modbus TCP/IP Lenze i550
0x23BE:003 Modbus TCP/IP diagnostics of last Rx/Tx data: Transmit offset P585.03 U8 0 Modbus TCP/IP Lenze i550
0x23BE:004 Modbus TCP/IP diagnostics of last Rx/Tx data: Last Tx message P585.04 OCTET[64] - (Read only) Modbus TCP/IP Lenze i550
0x23C0 POWERLINK communication U8 No action/no error [0] POWERLINK Lenze i550
0x23C1:004 POWERLINK settings: Node ID U8 0 POWERLINK Lenze i550
0x23C2:001 Active POWERLINK settings: IP address U32 - (Read only) POWERLINK Lenze i550
0x23C2:002 Active POWERLINK settings: Subnet U32 - (Read only) POWERLINK Lenze i550
0x23C2:003 Active POWERLINK settings: Gateway U32 - (Read only) POWERLINK Lenze i550
0x23C2:004 Active POWERLINK settings: Node ID U8 - (Read only) POWERLINK Lenze i550
0x23C2:005 Active POWERLINK settings: MAC Address OCTET[6] - (Read only) POWERLINK Lenze i550
0x23C2:007 Active POWERLINK settings: Tx length U8 - (Read only) POWERLINK Lenze i550
0x23C2:008 Active POWERLINK settings: Rx length U8 - (Read only) POWERLINK Lenze i550
0x23C3 POWERLINK switch position U8 - (Read only) POWERLINK Lenze i550
0x23C8:001 POWERLINK status: Network management U8 - (Read only) POWERLINK Lenze i550
0x23C9:001 POWERLINK error: Activation U16 - (Read only) POWERLINK Lenze i550
0x243C:001 Device: Ethernet commands: Device: Start firmware update U8 Off / ready [0] C Lenze i950
0x2440 Initiate WLAN U8 No action/no error [0] WLAN Lenze i550
0x2441:001 WLAN settings: IP address U32 192.168.178.1 WLAN Lenze i550
0x2441:002 WLAN settings: Netmask U32 255.255.255.0 WLAN Lenze i550
0x2441:003 WLAN settings: Gateway U32 192.168.178.1 WLAN Lenze i550