6AG1336-4GE00-2AB0
SIPLUS S7-300 SM 336 F 6 AI 15 bit based on 6ES7336-4GE00-0AB0 with conformal coating, -25…+60 °C, 70° with forced convection, fail-safe analog inputs for SIMATIC Safety, with HART support, up to category 4 (EN 954-1) /SIL3 (IEC 61508)/ PLE (ISO 13849), 1x 20-pole
Siemens spare part — S7-300 product cancellation (PM410, 1 October 2025); available as a spare part until 2033.
Termékkategória
Analóg modulokGyártó
SIEMENSTermékcsalád
S7-300| General information | |
|---|---|
| based on | 6ES7336-4GE00-0AB0 |
| Supply voltage | |
| Rated value (DC) | 24 V; ±5 % |
| Reverse polarity protection | Yes |
| Input current | |
| From power supply L+, typ. | 150 mA |
| from backplane bus 5 V DC, max. | 90 mA |
| Power loss | |
| Power loss, typ. | 4.5 W |
| Analog inputs | |
| Number of analog inputs | 6 |
| permissible input current for current input (destruction limit), max. | 40 mA |
| Input ranges | |
| Voltage | No |
| Current | Yes |
| Thermocouple | No |
| Resistance thermometer | No |
| Resistance | No |
| Input ranges (rated values), currents | |
| 0 to 20 mA | Yes |
| Input resistance (0 to 20 mA) | 150 Ω; typ. 150 ohms max. 175 ohms |
| 4 mA to 20 mA | Yes |
| Input resistance (4 mA to 20 mA) | 150 Ω; typ. 150 ohms max. 175 ohms |
| Cable length | |
| shielded, max. | 1 000 m |
| Analog value generation for the inputs | |
| Integration and conversion time/resolution per channel | |
| Resolution with overrange (bit including sign), max. | 16 bit; 15 bit + sign |
| Integration time (ms) | 20 ms @ 50 Hz, 16.7 ms @ 60 Hz |
| Interference voltage suppression for interference frequency f1 in Hz | f=n x (f1 ±0.5 %) |
| Encoder | |
| Connection of signal encoders | |
| for current measurement as 2-wire transducer | Yes |
| for current measurement as 4-wire transducer | Yes |
| Errors/accuracies | |
| Operational error limit in overall temperature range | |
| Current, relative to input range, (+/-) | 0.3 %; 60 µA |
| Basic error limit (operational limit at 25 °C) | |
| Current, relative to input range, (+/-) | 0.1 %; 20 µA |
| Interrupts/diagnostics/status information | |
| Diagnostics function | Yes |
| Alarms | |
| Diagnostic alarm | Yes |
| Diagnoses | |
| Diagnostic information readable | Yes |
| Diagnostics indication LED | |
| Fail-safe operation | Yes |
| Group error SF (red) | Yes |
| Encoder supply Vs (green) | No |
| Potential separation | |
| Potential separation analog inputs | |
| between the channels | Yes |
| between the channels and backplane bus | Yes |
| between the channels and the power supply of the electronics | Yes |
| Isolation | |
| Isolation tested with | 370V for 1 min |
| Standards, approvals, certificates | |
| CE mark | Yes |
| Highest safety class achievable in safety mode | |
| acc. to EN 954 | 4 |
| Performance level according to ISO 13849-1 | e |
| SIL acc. to IEC 61508 | SIL 3 |
| Ambient conditions | |
| Ambient temperature during operation | |
| min. | -25 °C; = Tmin; Startup @ -25 °C |
| max. | 60 °C; = T max; *+70 °C when forced convection at a minimum air speed of 0.3 m/s through the modules is ensured. If in the course of maintenance or automatic diagnosis it is determined that the admissible specified parameters have been exceeded, the modules should be subjected to a proof test (function check) by the manufacturer. |
| Ambient temperature during storage/transportation | |
| min. | -40 °C |
| max. | 70 °C |
| Altitude during operation relating to sea level | |
| Installation altitude above sea level, max. | 2 000 m |
| Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) |
| Relative humidity | |
| With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) |
| Resistance | |
| Use in stationary industrial systems | |
| to biologically active substances according to EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
| to chemically active substances according to EN 60721-3-3 | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
| to mechanically active substances according to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust, * |
| Use on ships/at sea | |
| to biologically active substances according to EN 60721-3-6 | Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request |
| to chemically active substances according to EN 60721-3-6 | Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
| to mechanically active substances according to EN 60721-3-6 | Yes; Class 6S3 incl. sand, dust; * |
| Usage in industrial process technology | |
| Against chemically active substances acc. to EN 60654-4 | Yes; Class 3 (excluding trichlorethylene) |
| Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04 | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) |
| Remark | |
| Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 | * The supplied plug covers must remain in place over the unused interfaces during operation! |
| Connection method | |
| required front connector | 20-pin |
| Dimensions | |
| Width | 40 mm |
| Height | 125 mm |
| Depth | 120 mm |
| Weights | |
| Weight, approx. | 350 g |
| Approvals / Certificates | |