Error codes

Filters
Showing 576–600 of 644
Title Keypad display Fault message ID Severity/response Product categories Operations
0x70A2 AO2 fault 28834

Warning

i550
0x7121 Pole pos. error 28961

Fault (configurable) Setting parameters: 0x2C60

i550, i950
0x7180 Mot max current 29056

Fault (configurable)

  • The event can only be reset after a blocking time. Setting parameters: 0x2D46:002 (P353.02)
i550
0x7305 Encoder error 29445

Warning (configurable) Setting parameters: 0x2C45 (P342.00)

i550
0x7385 F.fdb spd limit 29573

Warning

i550
0x7680 EPM full 30336

Warning

  • The parameter settings were not saved in the memory module.
i550
0x7681 EPM not present 30337

Fault

  • The default setting stored in the inverter firmware has been loaded.
  • The error cannot be reset by the user.
i550
0x7682 EPM invalid data 30338

Fault

  • The user parameter settings are lost.
  • The default settings were automatically loaded.
i550
0x7684 Save incomplete 30340

Warning

  • The user parameter settings were not fully saved.
  • At the next switch-on, the data stored are copied to the user memory.
i550
0x7689 data invalid OEM 30345

Warning

  • The user parameter settings were automatically loaded.
i550
0x768A Wrong EPM 30346

Fault

  • The default setting stored in the inverter firmware has been loaded.
  • The error cannot be reset by the user.
i550
0x7690 EPM-FW incomp. 30352

Fault

  • The data have been loaded into the RAM memory, but they are incompatible.
i550
0x7691 EPM: FW incomp. 30353

Fault

  • The data have been loaded into the RAM memory, but they are incompatible.
i550
0x7692 UserCU not match 30354

Fault

  • The data have been loaded into the RAM memory without being modified, and they are compatible.
  • The settings loaded must be accepted by the user (see remedy).
i550
0x7693 EPM PU size inco 30355

Fault

  • The data have been loaded into the RAM memory, but they are incompatible.
i550
0x7694 EPM new PU size 30356

Fault

  • The data have been loaded into the RAM memory without being modified, and they are compatible.
  • The settings loaded must be accepted by the user (see remedy).
i550
0x7695 InvalidChgovrCfg 30357

Warning

  • The parameter change-over function is deactivated.
i550
0x7696 Unkn. Par in EPM 30358

Information

i550
0x7697 Parameter loss 30359

Fault

  • The parameter settings changed have been lost.
i550
0x8112 TO expl. msg 33042

Warning (configurable) Setting parameters: 0x2859:006 (P515.06)

i550, i950
0x8114 TO overall comm 33044

Warning (configurable)

i550, i950
0x8115 (PAM) Time-out 33045

No response (configurable) Setting parameters: 0x2552:004 (P595.04)

i550
0x8116 MBTCP mast t-out 33046

Fault (configurable) Setting parameters: 0x2859:008 (P515.08)

i550
0x8117 MB.Keep Alive TO 33047

Fault (configurable) Setting parameters: 0x2859:009 (P515.09)

i550
0x8182 CAN: bus off 33154

Trouble (configurable)

  • Change to the "Bus-Off" communication status.
i550, i950
← Previous Page 24 of 26 Next →