6AV2128-3MB27-0BX0

6AV2128-3MB27-0BX0

SIMATIC HMI MTP1200 PRO, tartókarhoz (bővíthető, kör keresztmetszetű cső) és bővítőegységhez, 12.1" szélesképernyős TFT kijelző, 16 millió szín, PROFINET interfész, WinCC Unified Comfort V18-tól konfigurálható, nyílt forráskódú szoftvert tartalmaz, amely díjmentesen rendelkezésre áll.

Termékkategória
Unified Comfort panelek
Gyártó
SIEMENS
Termékcsalád
SIMATIC HMI
General information
Product type designationMTP1200 Unified Comfort PRO
Display
Design of displayTFT
Screen diagonal12.1 in
Display width261.1 mm
Display height163.2 mm
Number of colors16 777 216
Resolution (pixels)
Horizontal image resolution1 280 pixel
Vertical image resolution800 pixel
Backlighting
MTBF backlighting (at 25 °C)50 000 h
Backlight dimmableYes; 5-100 %
Control elements
Keyboard
Numeric keyboardYes; Onscreen keyboard
alphanumeric keyboardYes; Onscreen keyboard
Touch operation
Design as touch screenYes
Design as multi-touch screenYes
Installation type/mounting
MountingSupport arm
Mounting positionvertical
Mounting in portrait format possibleNo
Mounting in landscape format possibleYes
maximum permissible angle of inclination without external ventilation35°
Supply voltage
Type of supply voltageDC
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Input current
Current consumption (rated value)0.6 A
Current consumption, max.1.3 A
Starting current inrush I²t0.5 A²·s
Power
Active power input, typ.14.4 W
Processor
Processor typeX86
Storage
FlashYes
RAMYes
Type of output
Info LEDNo
Power LEDNo
Error LEDNo
Acoustics
BuzzerYes
SpeakerNo
Time of day
Clock
Hardware clock (real-time)Yes
Software clockYes
retentiveYes; Back-up duration typically 6 weeks
synchronizableYes
Interfaces
Number of industrial Ethernet interfaces2; 2 ports (switch) + independent port
Number of RS 485 interfaces1; RS 422 / 485 combined
Number of RS 422 interfaces0; together with RS 485
Number of USB interfaces4; USB 3.1 Gen. 1 (type A)
Number of SD card slots2
Industrial Ethernet
Industrial Ethernet status LED2
Number of ports of the integrated switch2
Protocols
PROFINETYes
PROFINET IONo
Protocols (Ethernet)
TCP/IPYes
DHCPYes
SNMPYes
DCPYes
LLDPYes
Redundancy mode
Media redundancy
MRPYes
Further protocols
CANNo
EMC
Emission of radio interference acc. to EN 55 011
Limit class A, for use in industrial areasYes
Limit class B, for use in residential areasNo
Degree and class of protection
IP (at the front)IP65
IP (rear)IP65
NEMA (front)
Enclosure Type 4 at the frontYes
Enclosure Type 4x at the frontYes
Enclosure Type 12 at the frontYes
Standards, approvals, certificates
CE markYes
UKCA markYes
cULusYes
FM approvalYes
RCM (formerly C-TICK)Yes
KC approvalYes
EAC (formerly Gost-R)Yes
CCCYes
Use in hazardous areas
ATEX Zone 2Yes
ATEX Zone 22Yes
IECEx Zone 2Yes
IECEx Zone 22Yes
cULus Class I Zone 2, Division 2Yes
cULus Class II Division 2No
FM Class I Division 2Yes
FM Class II Division 2Yes
Marine approval
Germanischer Lloyd (GL)No
American Bureau of Shipping (ABS)No
Bureau Veritas (BV)No
Det Norske Veritas (DNV)No
Korean Register of Shipping (KRS)No
Lloyds Register of Shipping (LRS)No
Nippon Kaiji Kyokai (Class NK)No
Polski Rejestr Statkow (PRS)No
Chinese Classification Society (CCS)No
Ambient conditions
Ambient temperature during operation
Operation (vertical installation)
For vertical installation, min.0 °C
For vertical installation, max.45 °C
Operation (max. tilt angle)
At maximum tilt angle, min.0 °C
At maximum tilt angle, max.40 °C
Ambient temperature during storage/transportation
min.-20 °C
max.60 °C
Relative humidity
Operation, max.90 %; no condensation
Operating systems
proprietaryYes
Configuration
Message indicatorYes
Alarm system (incl. buffer and acknowledgment)Yes
Process value display (output)Yes
Process value default (input) possibleYes
Recipe managementYes
Configuration software
STEP 7 Basic (TIA Portal)No
STEP 7 Professional (TIA Portal)No
WinCC flexible CompactNo
WinCC flexible StandardNo
WinCC flexible AdvancedNo
WinCC Basic (TIA Portal)No
WinCC Comfort (TIA Portal)No
WinCC Advanced (TIA Portal)No
WinCC Professional (TIA Portal)No
WinCC Unified Basic Engineering (TIA Portal)No
WinCC Unified Comfort Engineering (TIA Portal)Yes; V18 or higher
WinCC Unified PC Engineering (TIA Portal)Yes; V18 or higher
Languages
Online languages
Number of online/runtime languages32
Project languages
Languages per project32
Functionality under WinCC Unified
LibrariesYes
Applications/options
WriterYes
CalcYes
Web browserYes
PDF ViewerYes
Media PlayerYes
SIMATIC WinCC Sm@rtServerYes
SIMATIC WinCC AuditYes
Unified CollaborationYes
Number of Visual Basic ScriptsNo
JavaScriptYes
Task planner
time-controlledYes
task-controlledYes
Help system
Number of characters per info text70
Number of message texts per message10
Message system
Number of alarm classes32
Bit messages
Number of bit messages9 000
Analog messages
Number of analog messages300
S7 alarm number procedureYes
System messages HMIYes
System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... )Yes
Number of characters per message512
Number of process values per message10
Acknowledgment groupsYes
Message indicatorNo
Message bufferYes; Configured as alarm archive
Circulating bufferYes
retentiveYes
maintenance-freeYes
Parameter set management (recipes)
Number of parameter set types750
Parameter sets per parameter set type2 000
Entries per parameter set1 000
Size of internal parameter set memory12 Mbyte
Parameter set memory expandableYes
Variables
Number of variables per device8 000
Number of variables per screen600
Limit valuesYes
StructuresYes
ArraysYes
Images
Number of configurable images1 200
FaceplateYes
Image objects
Number of objects per image800
Picture windowYes
Text fieldsYes
I/O fieldsYes
Graphic I/O fields (graphics list)Yes
Symbolic I/O fields (text list)Yes
Scalable Vector Graphics (SVG)Yes
Date/time fieldsYes
CheckboxYes
Option buttonYes
SwitchesYes
ButtonsYes
Graphic displayYes
IconsYes
Custom web displayYes
Geometric objectsYes
Complex image objects
Number of complex objects per screen40
Alarm viewYes
Trend viewYes
User viewYes
Status/controlYes
Parameter set displayYes
HTML browserYes
Bar graphsYes
SlidersYes
Pointer instrumentsYes
Analog/digital clockYes
Lists
Number of text lists per project750
Number of entries per text list750
Number of graphics lists per project750
Number of entries per graphics list750
Archiving
Number of archives per device50
Number of entries per archive500 000
Message archiveYes
Process value archiveYes
Archiving methods
Sequential archiveYes
Short-term archiveYes
Memory location
Memory cardYes
USB memoryYes
EthernetNo
Security
Number of roles50
Number of function rights20; number of predefined function rights
Number of users200
Password export/importYes
Central user administrationYes
Transfer (upload/download)
USBNo
EthernetYes
using external storage mediumYes
Process coupling
S7-1200Yes
S7-1500Yes
S7-200Yes
S7-300/400Yes
Number of S7 connections16
LOGO!Yes; as of WinCC Unified V20
WinACNo
SINUMERIKNo
SIMOTIONNo
Allen Bradley (EtherNet/IP)Yes
Allen Bradley (DF1)Yes
Mitsubishi (MC TCP/IP)Yes
Mitsubishi (FX)Yes
OMRON (FINS TCP)Yes
OMRON (Host Link)No
Modicon (Modbus TCP/IP)Yes
Modicon (Modbus RTU)Yes
OPC UA ClientYes
OPC UA ServerYes
Software Controller/Open ControllerYes
Service tools/configuration aids
Backup/Restore manuallyYes
Backup/Restore automaticallyYes
SimulationYes
Device switchoverYes
Peripherals/Options
PeripheralsPrinter, barcode reader
PrinterYes
SIMATIC HMI MM memory card: Multi Media CardNo
SIMATIC HMI SD memory card: Secure Digital memory cardYes
SIMATIC HMI CF memory card Compact Flash CardNo
USB memoryYes
SIMATIC IPC USB Flashdrive (USB stick)Yes
SIMATIC HMI USB stickYes
Network cameraYes
Mechanics/material
Enclosure material (front)
PlasticNo
AluminumYes
Stainless steelNo
Dimensions
Width of the housing front313 mm
Height of housing front225 mm; Without basic adapter
Weights
Weight (without packaging)5 kg
Approvals / Certificates