6AG1521-1FH00-7AA0
SIPLUS S7-1500 DI 16x230V AC BA na bázi 6ES7521-1FH00-0AA0 s ochranným lakováním, -40…+70 °C, modul digitálních vstupů, 16 kanálů ve skupinách po 4; zpoždění vstupu 20 ms; typ vstupu 1 (IEC 61131).
Kategorie produktu
Digitální modulyVýrobce
SIEMENSProduktová řada
S7-1500| General information | |
|---|---|
| Product type designation | DI 16x230VAC BA |
| Firmware version | |
| FW update possible | Yes |
| based on | 6ES7521-1FH00-0AA0 |
| Product function | |
| I&M data | Yes; I&M0 to I&M3 |
| Isochronous mode | No |
| Prioritized startup | Yes |
| Engineering with | |
| STEP 7 TIA Portal configurable/integrated from version | see entry ID: 109746275 |
| Operating mode | |
| DI | Yes |
| Counter | No |
| MSI | Yes |
| Power | |
| Power consumption from the backplane bus | 1 W |
| Power loss | |
| Power loss, typ. | 4.9 W |
| Digital inputs | |
| Number of digital inputs | 16; > +60 °C, number of simultaneously controllable inputs max. 8 |
| Digital inputs, parameterizable | No |
| Sourcing/sinking input | P-reading |
| Input characteristic curve in accordance with IEC 61131, type 1 | Yes |
| Input voltage | |
| Rated value (AC) | 230 V; 120/230 V AC, 50/60 Hz |
| for signal "0" | 0V AC to 40V AC |
| for signal "1" | 79V AC to 264V AC |
| Input current | |
| for signal "1", typ. | 11 mA; At 230 V AC/50 Hz and 6.5 mA at 120 V AC/50 Hz |
| Input delay (for rated value of input voltage) | |
| for standard inputs | |
| parameterizable | No |
| at "0" to "1", max. | 25 ms |
| at "1" to "0", max. | 25 ms |
| for interrupt inputs | |
| Parameterizable | No |
| for technological functions | |
| Parameterizable | No |
| Cable length | |
| shielded, max. | 1 000 m |
| unshielded, max. | 600 m |
| Encoder | |
| Connectable encoders | |
| 2-wire sensor | Yes |
| permissible quiescent current (2-wire sensor), max. | 2 mA |
| Interrupts/diagnostics/status information | |
| Diagnostics function | No |
| Alarms | |
| Diagnostic alarm | No |
| Hardware interrupt | No |
| Diagnoses | |
| Monitoring the supply voltage | No |
| Wire break | No |
| Short-circuit | No |
| Diagnostics indication LED | |
| RUN LED | Yes; green LED |
| ERROR LED | Yes; red LED |
| Monitoring of the supply voltage (PWR-LED) | No |
| Channel status display | Yes; green LED |
| for channel diagnostics | No |
| for module diagnostics | Yes; red LED |
| Potential separation | |
| Potential separation channels | |
| between the channels | No |
| between the channels, in groups of | 4 |
| between the channels and backplane bus | Yes |
| Permissible potential difference | |
| between different circuits | 250 V AC between the channels and the backplane bus; 500 V AC between the channels |
| Isolation | |
| Isolation tested with | 3 100 V DC |
| Standards, approvals, certificates | |
| Suitable for safety functions | No |
| Ecological footprint | |
| environmental product declaration | Yes |
| Global warming potential | |
| global warming potential, (total) [CO2 eq] | 18.9 kg |
| global warming potential, (during production) [CO2 eq] | 12.1 kg |
| global warming potential, (during operation) [CO2 eq] | 7.66 kg |
| global warming potential, (after end of life cycle) [CO2 eq] | -1.02 kg |
| Security | |
| signed firmware update | No |
| data integrity | No |
| Ambient conditions | |
| Ambient temperature during operation | |
| horizontal installation, min. | -40 °C; = Tmin (incl. condensation/frost) |
| horizontal installation, max. | 70 °C; = Tmax; > +60 °C number of simultaneously controllable inputs max. 8 |
| vertical installation, min. | -40 °C; = Tmin |
| vertical installation, max. | 40 °C; = Tmax |
| Altitude during operation relating to sea level | |
| Installation altitude above sea level, max. | 2 000 m |
| Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) |
| Relative humidity | |
| With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) |
| Resistance | |
| Coolants and lubricants | |
| Resistant to commercially available coolants and lubricants | Yes; Incl. diesel and oil droplets in the air |
| Use in stationary industrial systems | |
| to biologically active substances according to EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
| to chemically active substances according to EN 60721-3-3 | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
| to mechanically active substances according to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust, * |
| Use on ships/at sea | |
| to biologically active substances according to EN 60721-3-6 | Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request |
| to chemically active substances according to EN 60721-3-6 | Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
| to mechanically active substances according to EN 60721-3-6 | Yes; Class 6S3 incl. sand, dust; * |
| Usage in industrial process technology | |
| Against chemically active substances acc. to EN 60654-4 | Yes; Class 3 (excluding trichlorethylene) |
| Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04 | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) |
| Remark | |
| Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 | * The supplied plug covers must remain in place over the unused interfaces during operation! |
| Conformal coating | |
| Coatings for printed circuit board assemblies acc. to EN 61086 | Yes; Class 2 for high reliability |
| Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection |
| Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life |
| Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A | Yes; Conformal coating, Class A |
| Dimensions | |
| Width | 35 mm |
| Height | 147 mm |
| Depth | 129 mm |
| Weights | |
| Weight, approx. | 200 g |
| Approvals / Certificates | |